– 11 –
CD-XP200W
Figure 11-2
CD ERROR CODE DESCRIPTION
Error
Explanation
01
When Pickup set inner position, inner switch
cannot detect 'ON' level for 10 secs.
When tray moves to Open/Close, Open/Close switch
10*
cannot detect 'ON' level for 7 secs.
When disc table rotate to target position.
Clamp switch cannot detect 'ON' level for 7 secs.
When disc table set to Disc1 position for 1 st time,
11*
"CLAMP SW", "DISC NO SW" and "OPEN/CLOSE"
cannot detect 'ON' level for 14 secs.
31
When it changes to CD function, DSP cannot read
initial data.
T
T
EFBL
FDO
TE
Stopped
CH1=500 mV
DC 10:1
CH2=200 mV
DC 10:1
CH3=1 V
DC 10:1
500 ms/div
(500 ms/div)
NORM:20 kS/s
1
2
3
=Record Length=
Smoothing : ON
CH1 : 0.000 V
CH2 : 0.000 V
Main : 100K
Zoom : 2k
Mode : SINGLE
Type : EDGE CH1
Delay : 0.0 ns
Hold off : 0.2
µ
s
CH3 : 0.00 V
CH4 : 0.00 V
BW : FULL
=Trigger=
=Filter=
=Offset=
CH2
v/DIV
200 mV
1999/04/05 20:26:47
Test Stage
Frequency
Frequency
Display
Setting/
Adjusting
Parts
Instrument
Connection
CD SECTION
•
AM IF/RF
Signal generator: 400 Hz, 30%, AM modulated
*1. Input: Antenna
Output: TP302
*2. Input: Antenna
Output: TP301
TUNER SECTION
fL: Low-range frequency
fH: High-range frequency
AM IF
450 kHz
1,602 kHz
T351
*1
AM Band
—
531 kHz
(fL): T306
*2
Coverage
1.1
±
0.1 V
AM Tracking 990 kHz
990 kHz
(fL): T303
*1
Figure 11-1 ADJUSTMENT POINTS
Items adjusted automatically
(1) Offset adjustment (The offset voltage between the head
amplifier output and the VREF reference voltage is
compensated inside the IC.)
* Focus offset adjustment
* Tracking offset adjustment
(2) Tracking balance adjustment (waveform drawing
Fig. 11-2 EFBL)
(3) Gain adjustment (The gain is compensated inside the IC
so that the loop gain at the gain crossover frequency will
be 0 dB.)
* Focus gain adjustment
* Tracking gain adjustment
• Adjustment
Since this CD system incorporates the following automatic
adjustment functions, readjustment is not needed when
replacing the pickup. Therefore, different PWBs and pickups
can be combined freely.
Each time a disc is changed, these adjustments are
performed automatically. Therefore, playback of each disc
can be performed under optimum conditions.
AM IF
FM RF
TP302
FM IF
T301
T302
R356
T303
T306
IC301
L312
T351
CNP302
AM/FM LOOP
ANTENNA
FM BAND
COVERAGE fL
AM BAND
COVERAGE fL
AM TRACKING
fL
MAIN PWB
1
TP301
R316
SO302
FM ANTENNA
TERMINAL
* 'CHECKING'
If Error is detected, 'CHECKING' will be display instead of 'ER-
CD**' display. 'ER-CD**' display will only be display when
error had been detected for the 5 th times.
*1. Input: Antenna
Output: TP301
*2. Input: Antenna
Output: Speaker terminal
•
FM RF
Signal generator: 1 kHz, 40 kHz dev., FM modulated
FM Band
—
87.50 MHz
T301 (fL):
*1
Coverage
1.3 V
±
0.1 V
FM RF
98.00 MHz 98.00 MHz
L312
*2
(10-30 dB)
Test Stage
Instrument
Connection
Frequency Frequency
Display
Setting/
Adjusting
Point
•
FM IF
Signal generator: 10.7 MHz, FM modulated
IF
10.7 MHz
98 MHz
T302
*1
(Turn the
core of trans-
former T302
fully counter-
clock wise)
Test Stage
Instrument
Connection
Frequency Frequency
Display
Setting/
Adjusting
Point
*1. Input: Antenna
Output: TP301
Summary of Contents for CD-XP200W