– 21 –
CD-CH1000
Table Character display for test mode 1
In the destination display, a destination code is displayed. For the span display, "9" means 9 kHz/50 kHz, and "10" means 10/
100 kHz.
Item
Type
Auxiliary display
1 2 3 4
5 6 7 8 : 9 10 Auxiliary display Note
Test mode name
I
N I
T
I
A L
CD disc inserted
Operation
C D *
O P E N
Set-Up Complete Function
F I
N I
S H
Character display
Outline
While the unit is turned off, press the POWER key while holding down the VOLUME-DOWN and PANEL OP/CL keys to enter
the test mode selection mode. Then, the unit is started, the panel is opened, and the microcomputer's version/destination/span
is displayed. If the following data is entered from the keyboard while in the test mode selection mode, the unit directly enters
the specified test mode. This operation is applied to the main unit's keys only.
In the destination display, a destination code (H/W/U/J) is displayed. For the span display, "9" means 9 kHz/50 kHz, and "10"
means 10/100 kHz. All pictures will disappear except the characters.
By pressing the specific key, you can enter the test mode whose functions are as follows:
Menu display
Shortcut Key
Model
System
INITIAL
CD1 PLAY
ALL
Shipping status setting
SOFT_RESET
CD2 PLAY
ALL
Soft rest
CD
CD_TEST
CD1 EJECT
ALL
CD test
Tuner
TUN_PRESET
CD4 EJECT
ALL
Tuner test frequency preset
TUNER_TEST
CD5 EJECT
ALL
Tuner test
Outline of Test Mode
Item
Type
Auxiliary display
1 2 3 4
5 6 7 8 : 9 10 Auxiliary display Note
Version•Destination
V
*
•
*
Left adjust in the first line
:
Character display
Example: V1. 1_W:_9
Number
Destination
Span
Shipping status setting test mode
Purpose: To Set up the unit for shipping.
Function: To check the unit for a CD disc, and initialize all functions.
Operation: While checking for a CD disc, the test name (INITIAL) is displayed.
The initial operation for a CD disc is performed. In this operation, the unit is checked for a CD disc.
If a CD disc is found in the unit during the initial operation, "CD* OPEN" is displayed, the tray is opened (only for the
disc found first), and the unit is turned on via the CD function normally.
If no CD disc is found, the CD mechanism is placed in the chucking status.
After the unit is checked for discs, all settings are initialized, "FINISH" is displayed as in the sample display, and data entry is
prohibited including data to turn on or off the unit.
To exit the test mode
The unit returns to the normal operation through reset entry (hard).
TEST MODE
Name
Description
1
Shipping status setting
Sets up the unit for shipping.
2
Soft set setting
Initializes the unit.
3
CD test
Performs tests such as the CD mechanism test, hardware test,
and constant setting test.
4
Tuner test
Presets the test frequency.
frequency preset
5
Tuner preset clear setting
Clears all presets.
Summary of Contents for CD-CH1000
Page 78: ...CD CH1000 15 M E M O ...