4
STEP 1 - CABINET OR WALL OPENING
The opening in the wall or cabinet must be within the
following dimensions:
OPENING
RK49S27F
RK49S30F
A
24
11
/
16
" (627.1 mm) 24
13
/
16
" (630.2 mm)
Width (B)
27
1
/
8
" (689 mm)
30
1
/
8
" (765.2 mm)
Height (C)
20
1
/
4
" (514.5 mm)
20
1
/
4
" (514.5 mm)
D
1
1
/
4
" (31 mm)
2
11
/
16
" (67.5 mm)
E
2
1
/
2
" (64 mm)
2
1
/
2
" (64 mm)
F
1
3
/
16
" (30.8 mm)
1
3
/
16
" (30.8 mm)
G
4" (101.6 mm)
4" (101.6 mm)
Minimum
Depth (I)
20" (508 mm)
20" (508 mm)
Outlet should
NOT be in the shaded area H as indicated in
Figure 1.
Mounting
cleat
F
B
A
E
D
D
Top View
Front View
Shelf
Shelf
Cabinet
face
Bottom of flush cutout
H
C
B
I
G
G
Figure 1
NOTES
Dimension C above will result in
7
⁄
8
"
(23 mm) spaces
above and below the trim to allow for necessary intake and
exhaust air flow to ensure appliance does not overheat.
Do
not reduce this spacing as doing so will void the warranty
for any issues resulting from a lack of airflow.
NOTES
• Please allow minimum 3" (76 mm) wood gap between the
microwave oven cutout and the appliance cutout below
the microwave oven. See Figure 2.
3"
(76 MM)
Min.
Microwave cutout
Wall oven cutout
Figure 2
• The floor of the opening should be constructed of
plywood strong enough to support the weight of the
oven and floor load (about 100 pounds/45 kg). The floor
should be level and 90˚ with the face of the cabinet for
proper installation and operation of the oven. Be sure to
check the local building code as it may require that the
opening be enclosed with sides, ceiling and rear partition.
The proper functioning of the oven does not require the
enclosure.