R-350J
22
Sealer film
Backing film
Adhesive tape
Pin
Pin
Upper
Oven Hinge
Upper Oven
Hinge
Lower Oven
Hinge
Lower
Oven Hinge
Slit choke of
door panel
Choke Cover
Choke Cover
Door Frame
Putty Knife
DOOR REPLACEMENT
REMOVAL
1. Disconnect the power supply cord.
2. Open button and open the door slightly.
3. Insert a putty knife (thickness of about 0.5mm) into the gap
between the choke cover and door frame as shown in Figure
C-5 to free engaging parts.
4. Pry the choke cover by inserting a putty knife as shown Figure
C-5.
5. Release choke cover from door panel.
6. Now choke cover is free.
7. Release two (2) pins of door panel from two (2) holes of upper
and lower oven hinges by lifting up.
8. Now, door panel with door frame is free from oven cavity.
NOTE: When carrying out any repair to the door, do not
bend or warp the slit choke (tabs on the door panel
assembly) to prevent microwave leakage.
Figure C-5. Door Disassembly
9. Release door panel from ten (10) tabs of door frame.
10. Now, door panel with sealer film is free.
11. Tear sealer film from door panel.
12. Now, door panel is free.
13. Slide latch head upward and remove it from door frame with
releasing latch spring from door frame and latch head.
14. Now, latch head and latch spring are free.
15. Remove the door screen from the door frame.
16. Now, door screen is free.
Reinstall
1. Reinstall door screen to door frame.
2. Reinstall the latch spring to the latch head. Reinstall the latch
spring to the door frame. Reinstall latch head to door frame.
3. Reinstall door panel to door frame by fitting ten (10) tabs of
door frame to ten (10) holes of door panel.
4. Put sealer film on door panel. Refer to “Sealer Film” about
how to handle new one.
5. Catch two (2) pins of door panel on two (2) hole of upper and
lower oven hinges.
6. Reinstall choke cover to door panel by pushing.
Note: After any service to the door;
(A) Make sure that 1st. latch switch, 2nd. interlock relay
control switch and monitor switch are operating
properly. (Refer to chapter “Test Procedures”.).
(B) An approved microwave survey meter should be used
to assure compliance with proper microwave radiation
emission limitation standards.
After any service, make sure of the following :
1. Door latch heads smoothly catch latch hook through latch
holes and that latch head goes through center of latch hole.
2. Deviation of door alignment from horizontal line of cavity face
plate is to be less than 1.0mm.
3. Door is positioned with its face pressed toward cavity face
plate.
4. Check for microwave leakage around door with an approved
microwave survey meter. (Refer to Microwave Measurement
Procedure.)
Note:
The door on a microwave oven is designed to act as an
electronic seal preventing the leakage of microwave
energy from oven cavity during cook cycle. This function
does not require that door be air-tight, moisture
(condensation)-tight or light-tight. Therefore, occasional
appearance of moisture, light or sensing of gentle warm
air movement around oven door is not abnormal and do
not of themselves indicate a leakage of microwave
energy from oven cavity.
Figure C-6. Door Replacement
SEALER FILM
Installation
1. Put the adhesive tape on the backing film of the sealer film as
shown in Fig. C-7.
2. Tear the backing film by pulling the adhesive tape.
3. Put the pasted side of the sealer film on the door panel.
Figure C-7. Sealer film