7
R-310AK
R-330AK
R-330AW
Pin No.
Signal
I/O
Description
A
B
0.1 sec.
2 sec.
H : GND
L : -5V
H : GND
L : -5V
16.7 msec.
During cooking
H : GND
L : -5V
16.7 msec.
H : GND
L : -5V
P-HI
H : GND
L : -5V
H : GND
L : -5V
P-70
ON
ON
OFF
OFF
OFF
24 sec.
8 sec.
22
R70
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay (RY2). The
signals holds "L" level during microwave cooking
and "H" level while not cooking. In other cooking
modes (variable cooking) the signal turns to "H"
level and "L" level in repetition according to the
power level.
(ON and OFF times for other power level.)
23
PULSE
OUT
Signal to sound buzzer (2.0 kHz).
A: key touch sound.
B: Completion sound.
24
R72
OUT
Oven lamp, fan motor and turntable motor driving signal
To turn on and off shut off relay (RY1). The
square waveform voltage is delivered to the
RY1 driving circuit and RY2 control circuit.
25
R73
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to R60 - R63 terminal while one
of G8 line keys on key matrix is touched.
26
INT2
IN
Signal synchronized with commercial power source frequency.
This is the basic timing for time processing of LSI.
27
R81
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to R60 - R63 terminal while one
of G7 line keys on key matrix is touched.
28
R82
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to R60 - R63 terminal while one
of G6 line keys on key matrix is touched.
29
R83
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to R60 - R63 terminal while one
of G5 line keys on key matrix is touched.
30
R90
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to R60 - R63 terminal while one
of G4 line keys on key matrix is touched.
31
R91
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to R60 - R63 terminal while one
of G3 line keys on key matrix is touched.
32
R92
OUT
Terminal not used.
33
XIN
IN
Internal clock oscillation frequency setting input.
The internal clock frequency is set by inserting the capacitor and resistor circuit with respect
to XOUT terminal.
34
XOUT
OUT
Internal clock oscillation frequency control output.
Output to control oscillation input of XIN.
35
RESET
IN
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is supplied. Temporarily set "L"
level the moment power is supplied, at this time the LSI is reset. Thereafter set at "H" level.
36
HOLD
IN/OUT
Connected to GND.
37
VLC
IN
Signal synchronized with commercial power source frequency.
Signal similar to VSS.
38
COM1
OUT
Common data signal: COM1.
Connected to LCD (Pin No. C1)
39
COM2
OUT
Common data signal: COM2.
Connected to LCD (Pin No. C2)