Code
E540
E550
E577
Detail
02
03
10
01
02
03
04
Timing of detection
• The shift upper sensor has gone ON while the
tray is moving up.
• No clock is detected for 50 msec or more from
the shift motor clock sensor when the shift mo-
tor has been driven.
• A Start signal has been received although 24
VDC is not supplied from the host machine.
• The paddle does not leave the paddle home po-
sition sensor when the paddle motor has been
driven for 2 sec.
• The paddle does not return to the paddle home
position sensor when the paddle motor has been
driven for 2 sec.
• The swing guide does not leave the swing guide
home position sensor when the paddle motor
has been driven for 2 sec.
• The swing guide does not return to the swing
guide home position sensor when the paddle
motor has been driven for 2 sec.
Error
• Shift upper sensor
(PI15)
• Shift motor (M6)
• Shift motor clock
sensor (PI17)
• Power supply error
• Paddle motor (M2)
• Paddle home position
sensor (PI2)
• Swing guide home
position sensor (PI3)