LC-60LE635E(B),RU(B)/636E(B),S(B)/638E(B)
6 – 10
4) Communication failure details (Low-speed blinking: Flashes 3 times + High-speed blinking)
5) Other failure details (Low-speed blinking: Flashes 4 times + High-speed blinking)
Error type
Expression of Central Icon LED
Note: Basically, debug print logs are analyzed or
communication logs are analyzed by a bus monitor.
Initial communication
reception failure
Flashes once
(High speed)
H: ON
L: OFF
Initial communication from the main CPU is not received.
(Request for the monitor model No. is not received.)
Communication line failure or main CPU start-up failure.
Start-up confirmation
reception failure
Flashes twice
(High speed)
H: ON
L: OFF
Start-up reason confirmation from the main CPU cannot be
received.
(Startup communication until start-up reason notification command
is not received.)
Main CPU start-up failure or monitor microprocessor reception
failure.
Regular communica-
tion failure
Flashes 3 times
(High speed)
H: ON
L: OFF
Regular communication that is performed at 1 second intervals in
the normal operation is interrupted.
Main CPU operation failure or monitor microprocessor
reception failure.
Other communica-
tion failure
Flashes 5 times
(High speed)
H: ON
L: OFF
When a request (PM_REQ=H) is sent from the main microproces-
sor, the request command is not output from the main CPU, etc.
Main CPU operation failure or monitor microprocessor
reception failure.
Error type
Expression of Central Icon LED
Note: Pins are monitor microprocessor pins unless otherwise
specified (IC2001).
Monitor temperature
failure
Flashes once
(High speed)
H: ON
L: OFF
If the panel temperature is 60
C or more for 15s or more in a row,
CAUTION appears on the OSD (flashes in red in the lower right
screen).
If the panel temperature is 60
C or more for 25s or more in a row,
error standby is activated.
(MONITOR MAX TEMP on page (12/20) of the adjustment pro-
cess: Change AD value for temperature failure): Thermistor
Main failure
Flashes 3 times
(High speed)
H: ON
L: OFF
Main microprocessor detection error (CPU temperature error, etc.)
Details are displayed on page (1/20) of the adjustment process for
the main microprocessor.