LC-32X20E/S/RU, LC-37X20E/S/RU
3 – 12
5) R/C Operation [RC BUTTON]
6) Main Unit Operation [PANEL BUTTON]
7) MENU Operation [MENU BUTTON]
8) ODS Display [ON SCREEN DISPLAY]
9) Start Mode [INPUT MODE START]
Selection
“RESP0ND” or “NO RESPOND” is selectable. (Loop is provided.)
Default
RESP0ND
Function
R/C key operation is set.
When set to “NO RESPOND”, the R/C keys are disabled in the ordinary mode.
The power key (Power ON/Standby Key) is also disabled.
Exception
• Regardless of the setting contents, the process mode, inspection mode and PUBLIC_Mode Key are enabled.
• Regardless of the setting contents, all keys can be used while entering the process mode, inspection mode or
PUBLIC_Mode.
Remarks
The CARD function stops all functions including the input switching and direct key when set to “NO RESPOND”.
Selection
“RESP0ND” or “NO RESPOND” is selectable. (Loop is provided.)
Default
RESP0ND
Function
NO RESPOND: Excluding power supply (Video/Standby key), the main unit keys are disabled.
Exception
• Regardless of the setting contents, the start operation of the process mode, inspection mode and PUBLIC_Mode
is enabled.
• Regardless of the setting contents, all keys can be used while entering the process mode, inspection mode and
PUBLIC_Mode.
Selection
“RESP0ND” or “NO RESPOND” is selectable. (Loop is provided.)
Default
RESP0ND
Function
The MENU keys on the main unit and R/C MENU are disabled.
Exception
• Regardless of the setting contents, the start operation of the process mode, inspection mode and PUBLIC_Mode
is enabled.
• Regardless of the setting contents, all keys can be used whileentering the process mode, inspection mode or
PUBLIC_Mode.
Key that becomes
invalid excluding Default
besides MENU Key
because of setting
ON_TIMER, Auto Preset, Manual_Memory, and clock setting
All Direct Shift keys to the MENU display
Remarks
When set to “NO RESPOND”,
• ON_TIMER is set to “OFF”.
Selection
“YES” or “NO” is selectable. (Loop is provided.)
Default
YES
Function
When set to “ON”, the following OSD is not displayed.
Register, Setting, Adjustment MENU, Channel_Call, Volume Bar
In the case of Wide Model, if the following operation is performed, it is immediately switched (since MENU can not be
displayed).
Input switching
Keys which can be
enabled (Exquisite
example)
Brightness sensor, light control
Keys disabled when not
set to Default (Example)
Still screen, screen display, MENU, OFF_TIMER, A V Position, Wide Mode switch, Auto Instolation
Remarks
• When set to “ON”,
a) The OFF_TIMER (SLEEP TIMER) setting time is cleared.
Selection
“NORMAL”, “TV(*Channel)”, “INPUT1”, “INPUT2” (Loop is provided.)
Default
NORMAL
Function
When the power is ON, the input source or channel to start is set.
In the NORMAL mode, it follows the contents of Last_Memory.
Remarks
• When set to a mode other than “NORMAL”,
a) It is inhibited to display the Channel Setting MENU and to set the Channel.
b) On start with “ON_TIMER”, the set Channel of ON_TIMER is prior.
• When set to “NORMAL”, “Mode Fixed (START MODE FIXED)” is set to “VARIABLE” to inhibit the selection.
Summary of Contents for Aquos LC-42X20E
Page 5: ...LC 32X20E S RU LC 37X20E S RU 1 2 2 OPERATION MANUAL ...
Page 6: ...LC 32X20E S RU LC 37X20E S RU 1 3 ...
Page 7: ...LC 32X20E S RU LC 37X20E S RU 1 4 ...
Page 8: ...LC 32X20E S RU LC 37X20E S RU 1 5 ...
Page 9: ...LC 32X20E S RU LC 37X20E S RU 1 6 ...
Page 10: ...LC 32X20E S RU LC 37X20E S RU 1 7 3 DIMENSIONS Unit mm ...
Page 156: ...LC 32X20E S RU LC 37X20E S RU 8 26 M E M O ...
Page 190: ...LC 32X20E S RU LC 37X20E S RU 34 11 PACKING PARTS 㵘 S3 S3 S2 S1 S3 S5 S5 S4 S3 S6 ...