4) Other failure details (Flashes slowly 4 times and flashes fast)
Note
4. Monitor ERR STBY table
Error type
Center icon LED operation
Pins are monitor microcomputer pins unless other-
wise specified.
Monitor temperature
failure
Flashes fast once
H: On
L: Off
If the panel temperature is 60
°
C or more for 15 seconds
or more in a row, CAUTION appears on the OSD
(flashes in red in the lower right screen).
If the panel temperature is 60
°
C or more for 25 seconds
or more in a row, error standby is activated.
(MONITOR MAX TEMP on page 23 of the process A:
Change of temperature failure AD value): Thermistor
Main failure
Flashes fast 3 times
H: On
L: Off
Main microcomputer detection error (CPU temperature
error, etc.)
The details are displayed on page 1 of the process A of
the main microcomputer.
Outline:
Communication/Power failure detected by the monitor microcomputer is stored on EEPROM, and the last 4 abnormal states can be
confirmed in the process mode A.
Location:
Page 1 of the process mode A: MONITOR ERR CAUSE
“0” if there is no error. It is cleared to 0 on the last page of the process mode A.
Display
Error description
02
Start-up communication error 2
Initial communication from the main CPU is not received.
03
Start-up communication error 3
Only the initial communication is received.
04
Start-up communication error 4
Until panel information request reception
05
Start-up communication error 5
Until initialization completion reception
06
Start-up communication error 6
Until version notification transmission
07
Start-up communication error 7
Until start-up information notification transmission
08
Start-up communication error 8
Until start-up information response reception
09
Start-up communication error 9
Until time-out setting reception
0A
Communication error A
REQ time-out
0B
Communication error B
Restart time-out during the beginning of time acquisition start-up
0C
Communication error C
Ending sequence time-out
0D
Communication error D
Preset start-up time-out during completion
0E
Communication error E
download, start-up time-out
0F
Communication error F
Time acquisition time-out
11
Communication error H
Regular communication time-out
16
Panel-related error
Lamp failure
1A
Other error 2
Monitor temperature failure
1E
Power supply error 2
D_POW (DET_13V) failure
1F
Power supply error 3
D_POW (DET_D3V3) failure
21
Power supply error 5
Panel power failure
23
Other error 3
Error standby request from the main CPU