LC-26P50E
LC-32P50E
LC-37P50E
23
8/12
[TUNER]
1
TUNER TEST
ENTER
9/12
[M GAMMA INFO]
1
M GAMMA IN 1
98
W/B adjustment, gradation 1 input setting
2
M GAMMA IN 2
136
W/B adjustment, gradation 2 input setting
3
M GAMMA IN 3
248
W/B adjustment, gradation 3 input setting
4
M GAMMA IN 4
324
W/B adjustment, gradation 4 input setting
5
M GAMMA IN 5
396
W/B adjustment, gradation 5 input setting
6
M GAMMA IN 6
448
W/B adjustment, gradation 6 input setting
7
M GAMMA IN WRITE
OFF/ON
EEP writing of adjustment values
8
M GAMMA IN RESET
OFF/ON
Initialization of adjustment values
10/12
[M GAMMA 1-3]
1
M GAMMA R 1
196
W/B adjustment, gradation 1R adjustment value
2
M GAMMA G 1
196
W/B adjustment, gradation 1G adjustment value
3
M GAMMA B 1
196
W/B adjustment, gradation 1B adjustment value
4
M GAMMA R 2
272
W/B adjustment, gradation 2R adjustment value
5
M GAMMA G 2
272
W/B adjustment, gradation 2G adjustment value
6
M GAMMA B 2
272
W/B adjustment, gradation 2B adjustment value
7
M GAMMA R 3
496
W/B adjustment, gradation 3R adjustment value
8
M GAMMA G 3
496
W/B adjustment, gradation 3G adjustment value
9
M GAMMA B 3
496
W/B adjustment, gradation 3B adjustment value
10
M GAMMA WRITE
OFF/ON
EEP writing of adjustment values
11/12
[M GAMMA 4-6]
1
M GAMMA R 4
648
W/B adjustment, gradation 4R adjustment value
2
M GAMMA G 4
648
W/B adjustment, gradation 4G adjustment value
3
M GAMMA B 4
648
W/B adjustment, gradation 4B adjustment value
4
M GAMMA R 5
792
W/B adjustment, gradation 5R adjustment value
5
M GAMMA G 5
792
W/B adjustment, gradation 5G adjustment value
6
M GAMMA B 5
792
W/B adjustment, gradation 5B adjustment value
7
M GAMMA R 6
896
W/B adjustment, gradation 6R adjustment value
8
M GAMMA G 6
896
W/B adjustment, gradation 6G adjustment value
9
M GAMMA B 6
896
W/B adjustment, gradation 6B adjustment value
10
M GAMMA WRITE
OFF/ON
EEP writing of adjustment values
12/12
[ETC]
1
EEP SAVE
OFF/ON
Saving of adjustment values
2
EEP RESTORE
OFF/ON
Restoring of adjustment values
3
STANDBY CAUSE RESET
OFF/ON
Clearing of standby cause
4
AUTO INSTALLATION SW
0/1
0: unfinished 1: finish
5
COUNTRY
AUTO/EURO/UK/ITALY/FRANCE/RUSSIA
Setting of destination
Summary of Contents for AQUOS LC-26P50E
Page 49: ...LC 26P50E LC 32P50E LC 37P50E 51 M E M O ...
Page 63: ...76 6 5 4 3 2 1 A B C D E F G H LC 26P50E LC 32P50E LC 37P50E Side A Ë POWER Unit ...
Page 64: ...77 6 5 4 3 2 1 A B C D E F G H LC 26P50E LC 32P50E LC 37P50E Ë POWER Unit Side B ...
Page 111: ...8 7 1 10 9 6 5 4 3 2 1 A B C D E F G H 11 13 12 15 14 17 16 19 18 21 20 ËAV Unit 1 4 D3 D4 ...
Page 112: ...8 7 1 10 9 6 5 4 3 2 1 A B C D E F G H 11 13 12 15 14 17 16 19 18 21 20 ËAV Unit 2 4 D5 D6 ...
Page 113: ...8 7 1 10 9 6 5 4 3 2 1 A B C D E F G H 11 13 12 15 14 17 16 19 18 21 20 ËAV Unit 3 4 D7 D8 ...
Page 114: ...8 7 1 10 9 6 5 4 3 2 1 A B C D E F G H 11 13 12 15 14 17 16 19 18 21 20 ËAV Unit 4 4 D9 D10 ...
Page 125: ...8 7 1 10 9 6 5 4 3 2 1 A B C D E F G H 11 13 12 15 14 17 16 19 18 21 20 ËKEY Unit D11 D12 ...
Page 130: ...6 5 4 3 2 1 A B C D E F G H ËR C LED Unit D41 ...