100
PG-M20S
PG-M20X
DESCRIPTION OF SCHEMATIC
DIAGRAM
VOLTAGE MEASUREMENT CONDITION:
1. Voltages at test points are measured at the supply
voltage of AC 230V. Signals are fed by a colour bar
signal generator for servicing purpose and the above
voltages are measured with a 20k ohm/V tester.
WAVEFORM MEASUREMENT CONDI-
TION:
1. Waveforms at test points are observed at the supply
voltage of AC 230V. Signals are fed by a colour bar
signal generator for servicing purpose.
INDICATION OF RESISTOR & CAPACI-
TOR:
RESISTOR
1. The unit of resistance “
Ω
” is omitted.
(K=k
Ω
=1000
Ω
, M=M
Ω
).
2. All resistors are ± 5%, unless otherwise noted.
(J= ± 5%, F= ± 1%, D= ± 0.5%)
3. All resistors are 1/16W, unless otherwise noted.
4. All resistors are Carbon type, unless otherwise
noted.
C
: Solid
W
: Cement
S
: Oxide Film
T
: Special
N
: Metal Coating
CAPACITOR
1. All capacitors are
µ
F, unless otherwise noted.
(P=pF=
µµ
F).
2. All capacitors are 50V, unless otherwise noted.
3. All capacitors are Ceramic type, unless otherwise
noted.
(ML): Mylar
(TA): Tantalum
(PF): Polypro Film
(ST): Styrol
BESCHREIBUNG DES
SCHEMATISCHEN SCHALTPLANS
SPANNUNGSMESSUNGEN:
1. Spannungen an den Prüfpunkten werden bei einer
Netzspannung von 230V gemessen, Signale werden
für die Wartung mit einem Farbbalken-Signal
generator zugeführt, und Spannungen werden mit
einem Meßinstrument (20 k
Ω
/V) ermittelt.
SIGNALFORMMESSUNGEN:
1. Die Wellenformen an den Testpunkten werden bei
einer Netzspannung von 230V verfolgt. Signale
werden für die Wartung mit einem Farbbalken-Signal
generator zugeführt.
BEZEICHNUNG DES WIDERSTANDS UND
KONDENSATORS:
WIDERSTAND
1. Die Widerstandseinheit “
Ω
” wird weggelassen.
(K=k
Ω
=1000
Ω
, M=M
Ω
).
2. Alle Widerstände haben ± 5%, sofern nicht anders
angegeben.
(J= ± 5%, F= ± 1%, D= ± 0.5%)
3. Alle Widerstände haben 1/16W, sofern nicht anders
angegeben.
4. Alle Widerstände sind Kohletyp, sofern nicht anders
angegeben.
C
: Fest
W
: Zement
S
: Oxidefilm
T
: Spezial
N
: Metallüberzug
KONDENSATOR
1. Die Kapazitätseinheit ist
µ
F, sofern nicht anders
angegeben.
(P=pF=
µµ
F).
2. Alle Kondensatoren haben 50V, sofern nicht anders
angegeben.
3. Alle Kondensatoren sind Keramiktyp, sofern nicht
anders angegeben.
(ML): Mylar
(TA): Tantal
(PF): Polyprofilm
(ST): Styrol
CAUTION:
This circuit diagram is original one, therefore there may be a
slight difference from yours.
SAFETY NOTES:
1. DISCONNECT THE AC PLUG FROM THE AC
OUTLET BEFORE REPLACEING PARTS.
2. SEMICONDUCTOR HEAT SINKS SHOULD BE
REGARDED AS POTENTIAL SHOCK HAZARDS
WHEN THE CHASSIS IS OPERATING.
IMPORTANT SAFETY NOTICE:
PARTS MARKED WITH “
å
( ) ARE
IMPORTANT FOR MAINTAINING THE SAFETY OF
THE SET. BE SURE TO REPLACE THESE PARTS
WITH SPECIFIED ONES FOR MAINTAINING THE
SAFETY AND PERFORMANCE OF THE SET.
ACHTUNG:
bei diesem Schaltplan handelt es sich um den ursprünglichen.
Esönnen daher geringfügige Unterschiede zu dem lhrem bestehen.
SICHERHEITSANMERKUNGEN:
1. VOR DEM AUSWECHSELN VON TEILEN MUSS
U N B E D I N G T N E T Z S T E C K E R A U S D E R
NETZSTECKDOSE GEZOGEN WERDEN.
2. DIE WARMEABLEITER DER HALBLEITER SOLLTEN
BEIM BETRIEB DES CHASSIS ALS MÖGLICHE
URSACHEN VON GEFÄHRLICHEN ELEKTRISCHEN
SCHLÄGEN BETRACHTET WERDEN.
WICHTIGE SICHERHEITSANMERKUNGEN:
MIT “
å
( )BEZEICHNETEN TEILE SIND
BESONDERS WICHTIG FÜR DIE AUFRECHTERHALTUNG
DER SICHERHEIT . BEIM WECHDIESER TEILE SOLLTEN
DIE VORGESCHRIEBENEN TEILE IMMER VERWENDET
WERDEN, UM SOWOHL DIE SICHERHEIT ALS AUCH DIE
LEISTUNG DES GERÄTES AUFRECHTZUERHALTEN.
Summary of Contents for AN-60KT
Page 94: ...94 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X CHASSIS LAYOUT CHASSIS ANORDNUNG ...
Page 95: ...95 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 96: ...96 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X BLOCK DIAGRAM BLOCKCHALTBILD ...
Page 97: ...97 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 99: ...99 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 103: ...103 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 105: ...105 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 107: ...107 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 109: ...109 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 111: ...111 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 112: ...112 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X Ë INPUT UNIT 1 5 EINGANGSEINHEIT 1 5 ...
Page 113: ...113 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 114: ...114 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X Ë INPUT UNIT 2 5 EINGANGSEINHEIT 2 5 ...
Page 115: ...115 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 116: ...116 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X Ë INPUT UNIT 3 5 EINGANGSEINHEIT 3 5 ...
Page 117: ...117 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 118: ...118 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X Ë INPUT UNIT 4 5 EINGANGSEINHEIT 4 5 ...
Page 119: ...119 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 120: ...120 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X Ë INPUT UNIT 5 5 EINGANGSEINHEIT 5 5 ...
Page 121: ...121 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 122: ...122 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X Ë KEY UNIT 1 3 SCHLÜSSELEINHEIT 1 3 ...
Page 123: ...123 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 124: ...124 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X Ë KEY UNIT 2 3 SCHLÜSSELEINHEIT 2 3 ...
Page 125: ...125 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 126: ...126 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X Ë KEY UNIT 3 3 SCHLÜSSELEINHEIT 3 3 ...
Page 127: ...127 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 128: ...128 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X Ë PFC UNIT PFC EINHEIT ...
Page 129: ...129 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 130: ...130 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X Ë POWER UNIT NETZEINHEIT ...
Page 131: ...131 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 132: ...132 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X Ë PC I F UNIT 1 7 PC I F EINHEIT 1 7 ...
Page 133: ...133 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 134: ...134 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X Ë PC I F UNIT 2 7 PC I F EINHEIT 2 7 ...
Page 135: ...135 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 136: ...136 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X Ë PC I F UNIT 3 7 PC I F EINHEIT 3 7 ...
Page 137: ...137 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 138: ...138 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X Ë PC I F UNIT 4 7 PC I F EINHEIT 4 7 ...
Page 139: ...139 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 140: ...140 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X Ë PC I F UNIT 5 7 PC I F EINHEIT 5 7 ...
Page 141: ...141 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 142: ...142 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X Ë PC I F UNIT 6 7 PC I F EINHEIT 6 7 ...
Page 143: ...143 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 144: ...144 8 7 10 9 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X Ë PC I F UNIT 7 7 PC I F EINHEIT 7 7 ...
Page 145: ...145 17 16 19 18 15 14 13 12 11 10 PG M20S PG M20X ...
Page 150: ...150 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X PC I F Unit Side A PC I F Einheit Seite A ...
Page 151: ...151 6 5 4 3 2 1 A B C D E F G H PG M20S PG M20X PC I F Unit Side B PC I F Einheit Seite B ...