EN-1

ENGLISH

WARNING

 Do not pull or deform the power supply cord. 

Pulling and misuse of the power supply cord 

can result in damage to the unit and cause 

electrical shock.

 Be careful not to expose your body directly to 

the outlet air for a long time. It may affect your 

physical conditions. 

 When using the air conditioner for infants, 

children, elderly, bedridden, or disabled people 

make sure the room temperature is suitable for 

those in the room.

 Never insert objects into the unit. Inserting 

objects can result in injury due to the high 

speed rotation of internal fans.

 Ground the air conditioner without fail. Do not 

connect the grounding wire to gas pipe, water 

pipe, lightning rod or telephone grounding 

wire. Incomplete grounding may cause electric 

shock.

 If anything is abnormal with the air conditioner 

(ex. a burning smell), stop the operation 

immediately and turn the circuit breaker OFF. 

 The appliance shall be installed in accordance 

with national wiring regulations. Improper 

cable connection can cause the power supply 

cord, plug and the electrical outlet to overheat 

 If the supply cord is damaged, it must be 

replaced by the manufacturer or its service 

to avoid a hazard. Use only the manufacture-

 Do not splash or pour water directly on the 

unit. Water can cause electrical shock or 

equipment damage.

 Do not attempt to install/remove/repair the unit 

by yourself. Incorrect work will cause electric 

installation/removal/repair of the unit.

CAUTION

 Open a window or door periodically to 

ventilate the room, especially when using gas 

oxygen shortage.

 Do not operate the buttons with wet hand. It 

may cause electric shock.

 For safety, turn the circuit breaker off when not 

using the unit for an extended period of time.

 Check the outdoor unit mounting rack 

periodically for wear and to make sure it is 

 Do not put anything on the outdoor unit nor 

step on it. The object or the person may fall 

down or drop, causing injury.

 This unit is designed for residential use. Do not 

use for other applications such as in a kennel 

or greenhouse to raise animals or grow plants. 

 Do not place a vessel with water on the unit. 

If water penetrates into the unit, electrical 

insulations may deteriorate and cause electric 

shock.

 Do not block the air inlets nor outlets of the 

troubles. 

 Be sure to stop the operation and turn the 

circuit breaker off before performing any 

maintenance or cleaning. A fan is rotating 

inside the unit and you may get injured.

 This appliance is not intended for use  by 

persons (including children) with reduced 

physical, sensory or mental capabilities, or 

lack of experience and knowledge, unless they 

have been given supervision or instruction 

concerning use of the appliance by a persion 

responsible for their safety. Childern should be 

supervised to ensure that they do not play with 

the appliance.

 Make sure to connect the air conditioner 

to power supply of the rated voltage and 

frequency. Use of a power supply with 

improper voltage and frequency can result in 

 

-

  Install the unit in a place with minimal dust, 

fumes and moisture in the air.  

 Arrange the drain hose to ensure smooth 

-

ting of the room, furniture etc.

 Make sure a leak breaker or a circuit breaker 

is installed, depending on the installation 

location, to avoid electrical shock.

  IMPORTANT SAFETY INSTRUCTIONS .............EN-1

  PART NAMES .....................................................EN-2

  USING THE REMOTE CONTROL ......................EN-4

  AUXILIARY MODE ..............................................EN-4

  TIPS ON SAVING ENERGY ................................EN-4

  BASIC OPERATION ............................................EN-5

  OPERATION CONDITION ..................................EN-5

  ADJUSTING THE AIR FLOW DIRECTION .........EN-6

  POWERFUL JET OPERATION ...........................EN-6

  GENTLE COOL AIR ............................................EN-7

  PLASMACLUSTER OPERATION .......................EN-7

  COMFORT OPERATION ....................................EN-8

  BABY MODE OPERATION .................................EN-8

  TIMER OPERATION ...........................................EN-9

  SELF CLEAN OPERATION...............................EN-10

  DISPLAY BUTTON ............................................EN-10

  MAINTENANCE ................................................EN-11

  BEFORE CALLING FOR SERVICE ..................EN-12 

ENGLISH

Please  read  this  manual  carefully  before  using  the  product.    

This manual should be kept in a safe place for handy reference.

  CONTENTS

   IMPORTANT SAFETY 

INSTRUCTIONS

Summary of Contents for AH-A5UDL

Page 1: ... AH A5UDL AH A7UDL AH A9UDL UEY models AH A5UEY AH A9UEY OUTDOOR UNIT AU A5UHL AU A7UHL AU A9UHL AU A12UHL AU A5UDL AU A7UDL AU A9UDL AU A5UEY AU A9UEY Plasmacluster and Device of a cluster of grapes are registered trademarks or trademarks of Sharp Corporation No Reg I 15 STID44 03001 0616 PENDINGIN RUANGAN TIPE SPLIT PETUNJUK PENGOPERASIAN ...

Page 2: ...AH AP9SSY_OM_A863_En indd 2 2015 3 26 9 29 14 ...

Page 3: ...it nor step on it The object or the person may fall down or drop causing injury This unit is designed for residential use Do not use for other applications such as in a kennel or greenhouse to raise animals or grow plants Do not place a vessel with water on the unit If water penetrates into the unit electrical insulations may deteriorate and cause electric shock Do not block the air inlets nor out...

Page 4: ... Lamp Green 10 TIMER Lamp orange 11 PLASMACLUSTER Lamp blue For UHL models only 9 1 2 3 4 5 6 7 8 11 10 9 10 OUTDOOR UNIT 12 13 14 15 12 13 14 15 12 Inlet Air 13 Refrigerant Pipe and Cable 14 Drainage Hose 15 Outlet Air AU A5UHL AU A5UDL AU A5UEY AU A7UHL AU A7UDL AU A9UHL AU A9UDL AU A9UEY AU A12UHL UDL UEY models UHL models ...

Page 5: ...18 DISPLAY Button For UHL models only 19 SWING Button horizontal direction For UHL models only REMOTE CONTROL 9 1 2 3 4 5 6 7 8 13 12 11 10 14 16 19 18 15 17 20 MODE Symbols AUTO COOL DRY 21 PLASMACLUSTER Symbol For UHL models only 22 GENTLE COOL AIR Symbol 23 SELF CLEAN Symbol For UHL models only 24 COMFORT Symbols 25 FAN SPEED Symbols AUTO Manual setting 26 POWERFUL JET Symbol 27 TEMPERATURE Ind...

Page 6: ...ransmission of the signal Do not leave the remote control in direct sunlight or near a heater Protect the remote control from moisture and shock 7 m Receiver window Use this mode when the remote control is not available TO TURN ON Press the AUX button The green OPERATION lamp will light up and the unit will start operating in the AUTO mode The fan speed and temperature setting are set to AUTO TO T...

Page 7: ...tomatically selected according to the room temperature when the unit is turned on DRY MODE The fan speed is preset to AUTO and cannot be changed WHEN POWER FAILURE OCCURES This air conditioner has a memory function to store setting when a power failure occurs After power recovery the unit will automatically re start in the same settings which were active before the power failure except for TIMER P...

Page 8: ...densation may result NOTE The adjustment range is narrower than the swing range in order to prevent condensation from dripping ADJUSTING THE AIR FLOW DIRECTION POWERFUL JET OPERATION The air conditioner works at the maximum power and optimum louver direction to make the room cool rapidly 1During operation press the POWERFUL JET button The remote control will display The temperature display will go...

Page 9: ...be memorized and it will be activated the next time you turn on the unit To perform PLASMACLUSTER operation in FAN only mode press the PLASMACLUSTER button when the unit is not operating The mode symbol of the remote control will go off and the fan speed cannot be set to AUTO For UHL models only Plasmacluster ions released into the room will reduce some airborne mold 1 During operation press the P...

Page 10: ...T button again COMFORT OPERATION 1 For UHL models only Soft quiet and clean operation cools a room with well optimized for intants 1During operation press BABY MODE button The remote control will display Fan speed will be automatically set to LOW or SOFT Louvre will be set to GENTLE COOL AIR operation PLASMACLUSTER will be turned on TO CANCEL Press BABY MODE button again BABY MODE OPERATION 1 NOTE...

Page 11: ... hours in 1 hour increments The TIMER OFF and TIMER ON can not be set together When the temperature is set during timer setting the temperature will show in the display for 5 sec onds and then return to the timer diaplay If a power failure occurs while the TIMER is set the TIMER setting will be cancelled and will not be retrieved even after the power is restored TIMER OFF When the TIMER OFF is set...

Page 12: ...ungus with Plasmacluster ions and dry inside of the unit Utilize the operation at seasonal change over terms or every 4 months 1Press the SELF CLEAN button when the unit is not operating The remote control will display The blue PLASMACLUSTER lamp will light up The unit will stop operation after 40 minutes TO CANCEL Press the SELF CLEAN button The blue PLASMACLUSTER lamp will turn off NOTE You cann...

Page 13: ...perate the unit in the SELF CLEAN operation to thoroughly dry inside the unit 2 Stop the operation and unplug the unit Turn of the circuit breaker if you have one exclusively for the air conditioner 3 MAINTENANCE BEFORE AIR CON DITIONER SEASON 1 dirty 2 Make sure that nothing obstructs the air inlet or outlet CLEANING THE UNIT AND THE RE MOTE CONTROL Wipe them with a soft cloth Do not directly spl...

Page 14: ...ter it is turned off The unit will not operate immediately after the mode is changed This is to protect the unit Wait 3 minutes before operating the unit ODORS Carpet and furniture odors that entered into the unit may be sent out from the unit CRACKING NOISE This sound is generated by the friction of the unit expanding or contracting due to a tempera ture change MIST SEEN AT INDOOR AIR OUTLET In c...

Page 15: ...han tindakan akan menyebabkan korslet kebocoran air kebakaran dll Konsultasikan dengan dealer atau petugas servis ahli untuk pemasangan pembuangan perbaikan alat PERHATIAN Buka jendela atau pintu secara berkala untuk ventilasi udara terutama apabila menggunakan perangkat gas Kurangnya ventilasi dapat menyebabkan kekurangan oksigen Jangan menekan tombol dengan tangan yang basah Ini dapat menyebabka...

Page 16: ...n Keluar Udara 9 Lampu OPERASIONAL hijau 10 Lampu TIMER oranye 11 Lampu PLASMACLUSTER biru Untuk model UHL saja UNIT DALAM RUANGAN NAMA SUKU CADANG UNIT LUAR RUANGAN 12 13 14 15 12 13 14 15 12 Saluran Masuk Udara 13 Pipa Refrigeran dan Kabel 14 Selang Pembuangan 15 Saluran Keluar Udara AU A5UHL AU A5UDL AU A5UEY AU A7UHL AU A7UDL AU A9UHL AU A9UDL AU A9UEY AU A12UHL model UDL UEY model UHL ...

Page 17: ...l RESET 18 Tombol DISPLAY Untuk model UHL saja 19 Tombol SWING arah horizontal Untuk model UHL saja 20 Simbol MODE OTOMATIS DINGIN KERING 21 Simbol PLASMACLUSTER Untuk model UHL saja 22 Simbol HEMBUSAN LEMBUT UDARA SEJUK 23 Simbol PEMBERSIHAN OTOMATIS Untuk model UHL saja 24 Simbol COMFORT 25 Simbol KECEPATAN KIPAS OTOMATIS Pengaturan manual 26 Simbol POWERFUL JET 27 Indikator SUHU 28 Simbol BABY ...

Page 18: ...an meletakkan remote control di bawah sinar matahari langsung atau di dekat pemanas Lindungi remote control dari kelembaban dan guncangan MODE TAMBAHAN MENGGUNAKAN REMOTE CONTROL Gunakan mode ini apabila remote control tidak tersedia UNTUK MENGHIDUPKAN Tekan tombol AUX Lampu OPERASIONAL warna hijau akan menyala dan unit akan mulai beroperasi dalam mode OTOMATIS Pengaturan kecepatan kipas dan suhu ...

Page 19: ...nan bawaan dapat mencegah agar unit tidak beroperasi apabila digunakan di luar kisaran tersebut Kemungkinan dapat terbentuk kondensasi di saluran udara keluar apabila unit dioperasikan terus menerus dalam mode DINGIN atau KERING saat kelembaban di atas 80 KONDISI PENGOPERASIAN CATATAN MODE OTOMATIS Dalam mode OTOMATIS pengaturan suhu dan mode dipilih secara otomatis berdasarkan suhu ruangan saat u...

Page 20: ...gkinan akan terjadi kondensasi CATATAN Kisaran pengaturan lebih sempit dari kisaran ayunan untuk mencegah agar kondensasi tidak menetes Pendingin ruangan bekerja pada daya maksimum dan arah bilah optimal untuk membuat ruangan agar cepat dingin 1 Selama pengoperasian tekan tombol POWERFUL JET Remote control akan menampilkan Tampilan suhu akan hilang Bilah hembusan udara vertikal akan disetel mengar...

Page 21: ...ARA SEJUK selama operasi POWERFUL JET berlangsung Untuk model UHL saja Ion Plasmacluster yang dilepaskan ke ruangan akan mengurangi beberapa jamur di udara 1 Selama pengoperasian tekan tombol PLASMACLUSTER Remote control akan menampilkan Lampu PLASMACLUSTER warna biru akan menyala UNTUK MEMBATALKAN Tekan lagi tombol PLASMACLUSTER Lampu PLASMACLUSTER warna biru akan mati 1 CATATAN Penggunaan operas...

Page 22: ...FORT Untuk model UHL saja Pengoperasian yang lembut tenang dan bersih mendinginkan ruangan secara optimal bagi bayi 1 Selama pengoperasian tekan tombol BABY MODE Remote control akan menampilkan Kecepatan kipas akan secara otomatis tetap RENDAH atau LEMBUT Bilah akan disetel pada pengoperasian HEMBUSAN LEMBUT UDARA SEJUK PLASMACLUSTER akan dihidupkan UNTUK MEMBATALKAN Tekan lagi tombol BABY MODE PE...

Page 23: ...itian setengah jam dan dari 10 jam hingga 12 jam ketelitiannya adalah 1 jam TIMER MATI dan TIMER HIDUP tidak dapat disetel bersamaan Apabila suhu ditetapkan selama timer aktif suhu akan ditampilkan di layar selama 5 detik kemudian kembali ke tampilan timer Apabila listrik mati saat TIMER sedang aktif pengaturan TIMER akan dibatalkan dan tidak akan aktif kembali setelah listrik pulih kembali TIMER ...

Page 24: ...geringkan bagian dalam unit Lakukan operasi ini saat perubahan musim dalam jangka melebihi atau setiap 4 bulan sekali 1 Tekan tombol CLEAN saat unit tidak sedang beroperasi Remote control akan menampilkan Lampu PLASMACLUSTER warna biru akan menyala Unit akan berhenti beroperasi setelah 40 menit UNTUK MEMBATALKAN Tekan tombol CLEAN Lampu PLASMACLUSTER warna biru akan mati 1 CATATAN Anda tidak dapat...

Page 25: ...gan memercikkan atau menuang air secara langsung ke unit Air dapat menyebabkan korslet atau kerusakan alat Jangan menggunakan air panas thinner bubuk gosok atau bahan pelarut kuat PEMELIHARAAN SETELAH SESI PENDINGINAN UDARA 1 Jalankan unit dalam operasi PEMBERSIHAN OTOMATIS untuk mengeringkan bagian dalam unit dengan seksama 2 Hentikan operasi dan cabut kabel unit Matikan pemutus sirkuit apabila A...

Page 26: ...ntuk model UHL saja UDARA BERBAU DIHEMBUSKAN SALURAN KELUAR PLASMACLUSTER Ini adalah bau ozon yan g dihasilkan dari generator Ion Plasmacluster Konsentrasi ozon sangat kecil paparan tidak akan mempengaruhi kesehatan Anda Ozon yang dibuang ke udara luar akan diuraikan dengan mudah dan kepadatannya di dalam ruangan tidak akan bertambah SUARA MENDENGUNG RENDAH Ini adalah suara unit yang menghasilkan ...

Page 27: ......

Page 28: ...Printed in Thailand TINSEA990JBRZ 16J TH PT SHARP TRADING INDONESIA Kawasan Industri KIIC Jl Harapan Raya Lot LL 1 2 Gedung No 01 Desa Sirnabaya Kec Teluk Jambe Timur Kabupaten Karawang 41361 ...

Reviews: