35
AH-X08BE/10BE/13BE
AY-X08BE/10BE/13BE
AY-X08BE-C/10BE-C
AU-X08BE/10BE/13BE
AE-X08BE/10BE/13BE
AE-X08BE-C/10BE-C
REFRIGERATION CYCLE
Figure R-1. Refrigeration Cycle for AH-X08BE/10BE/13BE
Figure R-2. Refrigeration Cyclefor AY-X08BE/X08BE-C/10BE/10BE-C/13BE
1
2
Capillary tube
3
Outdoor unit
Condenser
Evaporator
Indoor unit
Compressor
Flare coupling
Flare coupling
Silencer
4
3-way
valve
2-way
valve
Accumulator
s
1
4
C
2
Capillary
tube A
Capillary
tube B
Capillary
tube C
(2 pieces)
Accumulator
3
Strainer
Heating
Cooling
Outdoor unit
Condenser
Evaporator
Indoor unit
Reverse valve
Comp-
ressor
Flare coupling
Flare coupling
3-way
valve
2-way
valve
Silencer
Coil