32U-S610
12
Separation Adjustment
1. Connect the rms voltmeter to pin (39) of IC3001.
2. Receive the following composite stereo signal 1.
Composite stereo signal: 30% modulation, left
channel only, noise reduction on, 300Hz
3. Enter the service mode and select the service
adjustment "M04".
4. Adjust the data until the AC voltage reading of the
RMS voltmeter is minimum.
5. Receive the following composite stereo signal 2.
Stereo signal: 30% modulation, left channel only,
noise reduction on, 3kHz
6. Enter the service mode and select the service
adjustment "M05".
7. Adjust the data until the AC voltage reading of the
rms voltmeter is minimum.
8. Take the above steps 1 thru 7 again for fine
adjustment.
Ë
P-IN-P ADJUSTMENT
P-IN-P Y-LEVEL Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P01".
3. Adjust "P01" data value to obtain normal contrast
level.
P-IN-P TINT Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P02".
3. Adjust data value to "29".
P-IN-P COLOR Adjustment
1. Receive a good local channel.
2. Make sure the customer color control is set to center
position.
3. Enter the service mode and select the service
adjustment "P03".
4. Adjust "P03" data value to obtain normal color level.
P-IN-P Y-OFF SET Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P04".
3. Adjust data value to "09".
P-IN-P H-POSITION Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P05".
3. Adjust data value to "0A".
P-IN-P BURST GATE PULSE (for MAIN)
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P06".
3. Adjust data value to "00".
P-IN-P FREERUN
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P07".
3. Adjust data value to "0B".
P-IN-P TINT-INPUT Adjustment
1. Receive the composite signal.
2. Enter the service mode and select the service
adjustment "P08".
3. Adjust data value to "24".
Summary of Contents for 32U-S610
Page 13: ...32U S610 6 5 4 3 2 1 A B C D E F G H 13 CHASSIS LAYOUT ...
Page 14: ...32U S610 6 5 4 3 2 1 A B C D E F G H 14 BLOCK DIAGRAM ...
Page 16: ...17 32US610 16 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H ...
Page 17: ...19 32US610 18 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H ...
Page 18: ...32U S610 6 5 4 3 2 1 A B C D E F G H 20 SCHEMATIC DIAGRAM CRT Unit ...
Page 19: ...22 32US610 21 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H ...
Page 20: ...32U S610 24 23 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM P IN P Unit ...
Page 21: ...32U S610 6 5 4 3 2 1 A B C D E F G H 25 SCHEMATIC DIAGRAM MTS MODULE Unit ...
Page 23: ...32U S610 6 5 4 3 2 1 A B C D E F G H 27 PWB A MAIN Unit Chip Parts Side ...