Vertical-Size and Linearity Adjustments
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D03" for V-size.
3. Adjust the "D03" bus data to get the proper V-size.
4. For V-linearity adjustment, select data bus "D05" and
adjust to get the proper vertical linearity.
Note: Aging for 10 min before adjustment. After the
adjustment of V-center and V-size, re-
adjustment for this V-line.
Vertical Phase Adjustment
1. Enter the service mode and select the service
adjustment "D01".
2. Adjust "D01" data value so that picture is centered.
Horizontal Position Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D02".
3. Adjust "D02" data value so that picture is centered.
Caption Position Adjustment (Horizontal)
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "EX2".
3. A black text box appears on the screen. (see
Figure
B. below)
4. Adjust "EX2" data value so that text box is positioned
in the center of the screen.
Figure B.
SERVICE
ADJUST
DATA(Hex)
POSITION
ITEM
32U-S50/60, 36U-S60
OP1
OPTION1
130
OP2
OPTION2
31
Horizontal-Size Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D04" for H-size.
3. Adjust the "D04" bus data to get the proper H-size.
EW-Parabola
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D07" for EW parabola.
3. Adjust the "D07" bus data to get the proper vertical
straight line for both left and right side.
EW-Trapezium
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D08" for EW-Trapezium.
3. Adjust the "D08" bus data to get the best position
display.
EW-Corner
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D09" for EW-Corner.
3. Adjust the "D09" bus data to get the best linearity for
4 corner points.
Other Adjustments
1. Enter the service mode.
2. Adjust the following data values as listed below.
Summary of Contents for 32U-S50
Page 4: ...4 32U S50 32U S60 36U S60 LOCATION OF USER S CONTROL 32U S50 32U S60 36U S60 ...
Page 12: ...12 6 5 4 3 2 1 A B C D E F G H 32U S50 32U S60 36U S60 MODELS 32U S50 60 CHASSIS LAYOUT ...
Page 13: ...13 6 5 4 3 2 1 A B C D E F G H 32U S50 32U S60 36U S60 MODEL 36U S60 CHASSIS LAYOUT ...
Page 14: ...14 6 5 4 3 2 1 A B C D E F G H 32U S50 32U S60 36U S60 MODELS 32U S50 60 BLOCK DIAGRAM ...
Page 15: ...15 6 5 4 3 2 1 A B C D E F G H 32U S50 32U S60 36U S60 MODEL 36U S60 BLOCK DIAGRAM ...
Page 29: ...36 6 5 4 3 2 1 A B C D E F G H 32U S50 32U S60 36U S60 PWB A MAIN Unit Wiring Side ...
Page 30: ...37 6 5 4 3 2 1 A B C D E F G H 32U S50 32U S60 36U S60 PWB A MAIN Unit Chip Parts Side ...