10
32F630
32F631
SERVICE ADJUSTMENT
RF AGC Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "R01".
3. Set the data value to point where no noise or beat
appears.
4. Select another channel to confirm that no noise or
beat appears.
Note 1 : You will have to come out of the service
mode to select another channel.
Note 2 : Setting the data to "00" will produce a black
raster.
Screen Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "V03" and set the data value to "00" to
set the color level to minimum. (Record original data
code under adjustment "V03" before changing) You
may skip this step, if you selected a B/W picture or
monoscope pattern.
3. Select the service adjustment "V11" and adjust the
data value to "01", this turn off the luminance signal
(Y-mute).
4. Adjust the master screen control until the raster
darkens to the point where raster is barely seen.
5. Adjust the service adjustments "V06" red, "V07" green
and "V08" blue to obtain a good grey scale with
normal whites at low brightness level.
6. Select the service adjustment "V11" and reset data
to "00". Select the service adjustment "V03" and reset
data to obtain normal color level.
7. For component input, the data value of "V46" red,
"V47" green and "V48" blue is adjusted to follow the
data value of "V06", "V07" and "V08" respectively.
8. Reset the master screen control to obtain normal
brightness range.
A
B
White Balance Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "V03" and set to "00" (minimum
color)(Record original data code under adjustment
"V03" before changing). "V03" does not have to be
adjusted, if you selected a B/W picture or monoscope
pattern.
3. Alternately adjust the service adjustment data of
"V09" and "V10" until a good grey scale with normal
whites is obtained. (RF Input)
4. For component input, the data value of "V49" and
"V50" is adjusted to follow the data value of "V09"
and "V10" respectively.
5. Select the service adjustment "V03" and reset data
to obtain normal color level.
Sub-picture and Sub-Bright Adjustments
1. Receive the window pattern signal.
•
RF INPUT (TU51)
2. Get into service adjustment data "V01" and "V05" and
set the luminance as shown in figure "A" and "B" as
below respectively.
•
COMPONENT INPUT
3. Get in service adjustment data "V42" and "V45" and
set the luminance as shown in figure "A" and "B" as
below respectively.
LUMINESCENCE CONFIRMATION
A: 95
±
10cd/m
2
B: 1.5
±
0.5cd/m
2
NECESSARY
UNNECESSARY
ADJUSTMENT
PART REPLACED
IC2001
IC201
X
Data is stored in IC2101.
The adjustment is needed to compensate for characteristics of parts
Holding down both the VOL-up and CH-up buttons on the TV set at service mode for more than 2 seconds will
NOTES
X
IC2101
IC3001
CRT
Holding down both the VOL-up and CH-up buttons on the TV set in
the service mode for more than 2 seconds will automatically write the
Adjust items related to picture tube only.
Adjust items related to MTS only (M01~M20).
X
X
X
Summary of Contents for 32F630 - X-Flat Flat-Screen 32" TV
Page 14: ...13 32F630 32F631 CHASSIS LAYOUT 32F630 ...
Page 15: ...14 32F630 32F631 CHASSIS LAYOUT 32F631 ...
Page 16: ...15 32F630 32F631 BLOCK DIAGRAM 32F630 ...
Page 17: ...16 32F630 32F631 BLOCK DIAGRAM 32F631 ...
Page 21: ...23 32F630 32F631 22 8 7 10 9 6 5 4 3 17 16 19 18 15 14 13 12 11 32F630 ...
Page 26: ...32 32F630 32F631 6 5 4 3 2 1 A B C D E F G H CRT UNIT ...
Page 27: ...33 32F630 32F631 6 5 4 3 2 1 A B C D E F G H AUDIO UNIT ...
Page 29: ...35 32F630 32F631 6 5 4 3 2 1 A B C D E F G H PWB A MAIN Unit Chip Parts Side ...
Page 31: ...37 32F630 32F631 6 5 4 3 2 1 A B C D E F G H PWB H DF MODULE Unit Wiring Side ...