11
25N-M100/M180/S100/S180
CN25M10,CN25S18/20
SERVICE
NUMBER
DATA
ADJUSTMENT CONTENTS
ADJUSTMENT ITEM
RANGE
INITIAL VALUE
S01
PICTURE
55
00-7F
S02
TINT
46
00-7F
S03
COLOR
32
00-7F
S04
BRIGHTNESS
40
00-7F
S05
SHARPNESS
24
00-3F
Must be set to "28"
S06
VERTICAL PHASE
00
00-07
Must be set to "00"
S07
HORIZONTAL PHASE
12
00-1F
S08
RF-AGC
23
00-3F
S09
VERTICAL AMP
20
00-3F
S10
VCO
2C
00-7F
S11
R CUT-OFF
00
00-FF
S12
G CUT -OFF
00
00-FF
S13
B CUT-OFF
00
00-FF
S14
G GAIN
7F
00-FF
S15
B GAIN
7F
00-FF
S16
TRAP(3.58MHz)
00
00 or 01
Must be set to "00"
S17
BALANCE
20
00-3F
Must be set to "20"
S18
C.C.POSITION
17
00-7F
S19
Y-MUTE
00
00,01,03
00= NORMAL, 01= No Y, 03= No VERTICAL
S20
ENERGY SAVE OFFSET
20
00-3F
Must be set to "23"
S21
D.D.E. OFFSET
03
00-1F
Must be set to "03"
S22
OSD SETUP
00
00-03
Must be set to "00"
S23
TUNER SETUP
00
00,01
Must be set to "00"
OP1
OPTION 1 (Set to each mode)
00
00-FF
"B0"=25N-M100, "B3"=25N-M180,
"B3"=25N-S100, "B7"=25N-S180,
"A0"=CN25M10, "A7"=CN25S18, "A7"=CN25S20
OP2
OPTION 2
00
00-FF
"04"=25N-M100, "04"=25N-M180,
"A7"=25N-S100, "A7"=25N-S180,
"04"=CN25M10, "07"=CN25S18, "A7"=CN25S20
M01
MTS LEVEL
0A
00-0F
M02
STEREO-VCO
20
00-3F
M03
FILTER
1C
00-3F
M04
LOW SEPARATION
20
00-3F
M05
HIGH SEPARATION
1B
00-3F
Only for Models
25N-S100/180, CN25S18/20
NECESSARY
UNNECESSARY
ADJUSTMENT
NOTES
PART REPLACED
IC2001
IC2101
CRT
IC201
Data is stored in IC2101.
The adjustment is needed to compensate for characteristics
of parts including IC201 and MTS level (M01).
Holding down both the Vol-up/CH-down buttons on the TV
set in the service mode for more than 2 seconds will
automatically write the above initial values into IC2101. Then
perform a complete adjustment.
Adjust items related to picture tube only.
Holding down both the Vol-up/CH-down buttons on the TV set at service mode for more than 2 seconds will
automatically write the above initial values into IC2101.
Table - B
Adjust items related to MTS only (M01~M05).
IC3001
(25N-S100/180, CN25S18)
X
X
X
X
X
Table - A