MTS ADJUSTMENT
(Only for 25L-S100/180, CL25S18)
MTS Level Adjustment
1. Feed the following monaural signal to pin (14) of
IC3001.
Monaural signal : 300Hz, 245mVrms
2. Connect the rms voltmeter to pin (39) of IC3001.
3. Enter the service mode and select the service
adjustment "M01".
4. Adjust the data so that the rms voltmeter reads.
490 ±10mVrms.
MTS VCO Adjustment
1. Keep the unit in no-signal state.
2. Connect the frequency counter to pin (39) of IC3001.
3. Connect a capacitor (100µF, 50V) in between
po) side of C3005 and ground.
4. Enter the service mode and select the service
adjustment "M02"
5. Adjust the data so that the frequency counter reads.
62.94 ±0.75kHz.
Filter Adjustment
1. Feed the following stereo pilot signal to pin (14) of
IC3001 .
Stereo pilot signal: 9.4kHz, 600mVrms.
2. Enter the service mode and select the service
adjustment "M03".
3. Adjust the data at the point where "OK" appears on
the screen. The "OK" represents the approximate
center of the adjustable range of the data.
Separation Adjustment
1. Connect the rms voltmeter to pin (39) of IC3001.
2. Receive the following composite stereo signal 1.
Composite stereo signal: 30% modulation, left
channel only, noise reduction on, 300Hz
3. Enter the service mode and select the service
adjustment "M04".
4. Adjust the data until the AC voltage reading of the
rms voltmeter is minimum.
5. Receive the following composite stereo signal 2.
Stereo signal: 30% modulation, left channel only,
noise reduction on, 3kHz
6. Enter the service mode and select the service
adjustment "M05".
7. Adjust the data until the AC voltage reading of the
rms voltmeter is minimum.
8. Take the above steps 1 thru 8 again for fine
adjustment.
Summary of Contents for 25L-M100
Page 6: ...6 25L M100 180 S100 180 CL25M10 CL25S18 LOCATION OF USER S CONTROL 25L M100 CL25M10 ...
Page 7: ...7 25L M100 180 S100 180 CL25M10 CL25S18 LOCATION OF USER S CONTROL Continued 25L M180 ...
Page 8: ...8 25L M100 180 S100 180 CL25M10 CL25S18 LOCATION OF USER S CONTROL Continued 25L S100 ...
Page 9: ...9 25L M100 180 S100 180 CL25M10 CL25S18 LOCATION OF USER S CONTROL Continued 25L S180 CL25S18 ...
Page 23: ...23 25L M100 180 S100 180 CL25M10 CL25S18 17 16 19 18 15 14 13 12 11 10 ...
Page 25: ...25 25L M100 180 S100 180 CL25M10 CL25S18 17 16 19 18 15 14 13 12 11 10 ...
Page 27: ...27 25L M100 180 S100 180 CL25M10 CL25S18 17 16 19 18 15 14 13 12 11 10 ...
Page 29: ...29 25L M100 180 S100 180 CL25M10 CL25S18 17 16 19 18 15 14 13 12 11 10 ...
Page 31: ...31 25L M100 180 S100 180 CL25M10 CL25S18 17 16 19 18 15 14 13 12 11 10 ...
Page 33: ...33 25L M100 180 S100 180 CL25M10 CL25S18 17 16 19 18 15 14 13 12 11 10 ...
Page 35: ...35 25L M100 180 S100 180 CL25M10 CL25S18 17 16 19 18 15 14 13 12 11 10 ...
Page 37: ...37 25L M100 180 S100 180 CL25M10 CL25S18 17 16 19 18 15 14 13 12 11 10 ...