6
Service Mode Overview
1. Service mode is entered by SERVICE key input or CH-UP +VOL-DOWN input during reset.
2. Service mode is cleared by entering SERVICE key command during service mode.
3. If key input port (SERVICE) input is LOW, then it is in service mode.
4. During key input port (SERVICE) input is LOW, clearing service mode by key input SERVICE is disabled.
5. Service mode can be switched to 4 modes as follows by key input MENU;
SERVICE MODE
6. AFT processing is disabled during service mode. PLL setting data is set to fo data.
7. All user data are set to default during service mode. FAO and SPEAKER user settings are off and on respectively
in service mode. Energy Save is off.
8. Sleep timer, View timer, on timer and off timer are inactivated in Service mode.
9. Sound is muting in service mode except at Adjustment Items V20, M01, M03, M04, M05, and M06.
Adjustment mode
Setting mode
First mode of service mode when SERVICE key is
pressed.
First mode of service mode when local key
CH-UP + VOL-DOWN is pressed after MCU reset.
Option mode
Check mode
21V-FR
9
5S
Summary of Contents for 21V-FR95S
Page 25: ...25 WAVEFORMS 21V FR95S ...
Page 26: ...26 6 5 4 3 2 1 A B C D E F G H CHASSIS LAYOUT 21V FR95S DUNTKD373WE PR701 ...
Page 27: ...27 6 5 4 3 2 1 A B C D E F G H CRT BLOCK DIA GRAM 21V FR95S ...
Page 28: ...28 A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 MAIN BLOCK DIAGRAM AV OUT Q803 BUFFER 21V FR95S ...
Page 29: ...29 21V FR95S 10 11 12 13 14 15 16 17 18 19 ...
Page 30: ...30 A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 MTS BLOCK DIAGRAM 21V FR95S ...
Page 32: ...21V FR95S ...
Page 33: ...34 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM CRT Unit 21V FR95S ...
Page 34: ...35 6 5 4 3 2 1 A B C D E F G H 21V FR95S SCHEMATIC DIAGRAM MTS Unit ...
Page 37: ...38 6 5 4 3 2 1 A B C D E F G H 21V FR95S PWB B CRT Unit Wiring Side ...