![Sharp 20CT-250 Service Manual Download Page 5](http://html.mh-extra.com/html/sharp/20ct-250/20ct-250_service-manual_373399005.webp)
5
5-1
5-2
20CT
-250
INITIAL SETTINGS OF CHANNEL SELECTION DATA
(1) Make an entry of MCL1 in the service mode in order to set the following channel selection data to the
E
2
PROM. And select the POS1 channel. (An MCL2, -3 or -4 input makes different settings.)
* To go to the service mode, the data at the E
2
PROM’s addresses 00H thru 03H are read. If the data are not as
given below, the E
2
PROM is initialized according to the table below.
Address :
Data
00H
:
23H
02H
:
13H
01H
:
20H
03H
:
61H
E
2
PROM item
Data adjustable range
Data initial value
Remarks
(00H)
––––––––––
23H
(01H)
––––––––––
20H
(02H)
––––––––––
13H
(03H)
––––––––––
61H
R CUT OFF
0 ~
255
0
G CUT OFF
0 ~
255
0
B CUT OFF
0 ~
255
0
G DRIVE
0 ~
255
127
B DRIVE
0 ~
255
127
50Hz V-AMP
0 ~
127
58
50Hz V-LINEARITY
0 ~
31
16
50Hz S-CORRECTION
0 ~
127
67
*1
50Hz V-PHASE
0 ~
7
5
–3
*1
50Hz H-PHASE
0 ~
31
7
+5
*1
V-BLK ST 50
0 ~
63
58
→
63 (50Hz)
V-BLK SP 50
0 ~
127
25
60Hz V-AMP
0 ~
127
59
60Hz V-LINEARITY
0 ~
31
14
60Hz S-CORRECTION
0 ~
127
74
*2
60Hz V-PHASE
0 ~
7
2
*4
60Hz H-PHASE
0 ~
31
12
60Hz V BLK ST
0 ~
63
60
→
63 (60Hz)
60Hz V BLK SP
0 ~
127
20
SECAM R-Y
0 ~
15
10
SECAM B-Y
0 ~
15
6
SUB-CONTRAST
0 ~
255
255
*2
SUB-BRIGHT
0 ~
255
127
SUB-COLOUR
0 ~
255
110
SUB-TINT
0 ~
127
70
SUB-SHARPNESS
0 ~
63
28
Y SUB-CONTRAST
0 ~
31
18
*2
DT PAL TV/AV
0 ~
7
2/2
*2
DT SECAM TV/AV
0 ~
7
4/4
*2
DT NTSC TV/AV
0 ~
7
2/2
*2
DT B/W TV/AV
0 ~
7
2/2
*2
V-MUTE
ON/OFF
OFF
A/V 2
1/2
1
NVM
With all the adjustments complete, do not change the data of addresses 00H thru 03H. Other-
wise the E
2
PROM will be initialized when the AC power is turned on.
*1 : These data are additionally adjusted for 60Hz based on the 50Hz settings.
*2 : Unless otherwise specified, these data are fixed and need no adjustment.
*4 : Only 0 through 5 must be used in changing the data.
POS
RECEPTION FREQ (MHZ)
S-SYSTEM
1
48.25
B/G
2
62.25
B/G
3
77.25
D/K
4
175.25
B/G
5
182.25
B/G
6
183.25
D/K
7
191.25
D/K
8
196.25
D/K
9
210.25
B/G
10
224.25
B/G
11
471.25
B/G
12
487.25
I
13
503.25
B/G
14
575.25
B/G
15
599.25
B/G
16
621.25
–
17
639.25
D/K
18
703.25
B/G
19
735.25
I
20
767.25
B/G
POS
RECEPTION FREQ (MHZ)
S-SYSTEM
21
815.25
B/G
22
855.25
I
23
855.25
B/G
24
55.25
B/G
25
83.25
B/G
26
183.25
–
27
193.25
–
28
471.25
B/G
29
477.25
–
30
693.25
–
31
885.25
B/G
32
112.25
B/G
33
168.25
B/G
34
FREE
–
35
294.25
B/G
36
463.25
B/G
37
FREE
–
38
647.25
B/G
39
663.25
B/G
40
679.25
B/G
FACTORY SETTING
(1) The following key-in data have been factory-set for the E
2
PROM.
Item
Setting
SKIP
OFF
AFT
ON
C-SYSTEM
AUTO
S-SYSTEM
B/G
LAST POWER
ON
LAST TV/AV
TV
DIGIT
1DIG
LANGUAGE
THAI
BLUE BACK
ON
LAST POS
1
LAST FB POS
1
VOLUME
MIN
CONTRAST
MAX
COLOUR
CENT
BRIGHTNESS
CENT
TINT
CENT
SHARPNESS