22
Shark
®
Jetters
OPERATOR’S MANUAL
SJDDG-3011 • 8.914-324.0 • REV. 7/12
TROUBLESHOOTING
Detergent System Malfunction
PROBLEM
POSSIBLE CAUSE
REPAIR
WASHER FAILS
TO DRAW
DETERGENT
Detergent metering valve closed
or valve clogged or defective
Open detergent metering valve, following
procedure in operating instructions.
Back pressure in hose (when using
additional lengths of pressure hose)
Contact dealer for proper injector
size when adding lengths of hose.
Back pressure in pressure hose (when
using dual lance wand)
Use proper size flood nozzle in dual lance
wand (refer to parts breakdown).
Suction tube not below liquid surface
Completely submerge suction tube
and strainer in detergent solution.
Clogged or damaged suction strainer
Clean or replace strainer.
DETERGENT
SOLUTION TOO WEAK
Air leak in detergent suction tube or
inlet plumbing
Find air leak and clean or replace parts as
necessary.
Clogged detergent strainer
Clean or replace strainer.
DETERGENT
SOLUTION TOO
CONCENTRATED
Original detergent too concentrated
Dilute product as necessary to achieve
proper concentration.
DETERGENT IN
RINSE CYCLE
Dual lance wand or adjustable nozzle
holder in open position or detergent
metering valve open
Close dual lance wand adjustable
lance holder to achieve high pressure.
Close detergent metering valve.
DILUTION OF
DETERGENT
CONCENTRATE
DURING CYCLE
Worn or defective internal check valve
Repair or replace check valve or injector
parts as necessary.
Defective check valve in detergent tank
Replace parts as necessary.
TROUBLESHOOTING
Unloader Valve Malfunction
PROBLEM
POSSIBLE CAUSE
REPAIR
UNLOADER
CYCLES
Fitting leaking downstream
Tighten/replace fitting.
Piston or valve spring broken or worn
Replace parts as necessary.
Clogged nozzle
Clean or replace.
FLUID LEAKING
FROM BODY
O-ring worn or cut
Replace part as necessary.
UNLOADER
WILL NOT COME
TO PRESSURE
Foreign particle in valve
Replace or clean.
Nozzle worn or wrong size
Replace part as necessary.
Piston or valve worn
Replace part as necessary.
EXTREME
PRESSURE
SPIKES
Adjusting nut turned completely into unloader
Back off adjusting nut.
Clogged nozzle
Clean or replace.