SHARK CONCRETE GRINDERS
9
Problem Solving
Error
C
ode
Cause
Remedy
GFF
Ground Fault
Ground fault protection circuit action.
When ac motor drives measure the output
ground and the grounding power is more
than 50% than the rated current of ac
motor drive.
Note: The protection system aims at ac
motor driver instead of the human body.
1.Check if there is a short circuit
phenomenon or ground connection.
2.Confirm if IGBT power modules are
damaged or not.
3. Check the connection of side is
defective insulation or not.
LVA/LVN
Lvat Accel
The voltage of ac motor drive measuring
internal dc high voltage side is lower than
06-00 when accelerating.
1. Check if the input power and voltage
are normal or not.
2. Check if there is a sudden heavy load.
Orp
Phase Lacked
Phase lacked protection
1. Check the input power correct or not.
2. Check if machine is larger than 40HP.
If yes, check AC breaker is melting or not.
Summary of Contents for S460
Page 1: ...1 Shark S460 SAFETY OPERATORS MANUAL CAUTION Read the instruction manual before using ...
Page 10: ...SHARK CONCRETE GRINDERS 10 Parts Diagram Main ...
Page 11: ...SHARK CONCRETE GRINDERS 11 Parts Diagram Frame ...
Page 12: ...SHARK CONCRETE GRINDERS 12 Parts Diagram Control Switch ...
Page 13: ...SHARK CONCRETE GRINDERS 13 Parts Diagram Frame ...
Page 14: ...SHARK CONCRETE GRINDERS 14 Parts Diagram Wire Rack ...
Page 15: ...SHARK CONCRETE GRINDERS 15 Parts Diagram Frame Base ...
Page 16: ...SHARK CONCRETE GRINDERS 16 Parts Diagram Wheel Base ...
Page 17: ...SHARK CONCRETE GRINDERS 17 Parts Diagram Inverter Housing ...
Page 18: ...SHARK CONCRETE GRINDERS 18 Parts Diagram Gearbox ...
Page 19: ...SHARK CONCRETE GRINDERS 19 Parts Diagram Gearbox Housing ...
Page 20: ...SHARK CONCRETE GRINDERS 20 Single Phase Wire Colours Active Red Neutral Yellow Earth Green ...