background image

Step 1: Before filling the steam cleaner, 

make sure that the unit is NOT 

plugged in.

Step 2: Press locking trigger to ensure 

all internal pressure is released.

Step 3: Turn Safety Cap counter 

clockwise until removed.

Step 4: Release locking trigger.

Step 5: Add 28 fl. oz (800 cc) of water 

using the filling flask provided. 

Do not overfill. 

Replace 

Safety Cap by turning 

clockwise - press down firmly to 

tighten. Heating time is 

approximately 6 minutes. Filling 

the boiler with hot water will 

shorten heat up time.

Step 6: Plug the unit into a standard 

120 volt grounded wall 

receptacle. The power “On” 

light (Red) will light up.  

Step 7: Allow approximately 6 minutes 

for water vapor to reach its 

working temperature and 

pressure.  When unit is ready 

for use the red light will change 

to Green. 

Step 8: At the start, some water will 

come out from the nozzle. This 

is normal.

NOTE:

Disconnect steam cleaner from 

wall outlet before refilling. It is time to refill 

your steam cleaner when there is no more 

steam coming out of the nozzle.  Because 

the water tank is pressurized, use caution 

when opening to refill. Depress the trigger 

button while you unscrew the safety cap 

counterclockwise. Always let unit cool for 

5 minutes before refilling the unit with 

water. 

CAUTION: When refilling the 

appliance while it is still hot, the 

first drops of water might 

bubble up. 

WARNING:

This appliance is 

under pressure. After every use, 

press trigger button until all 

pressure has been released 

before removing safety cap. 

Allow unit to cool for five (5) 

minutes before refilling.

IMPORTANT:

Always insure that the 

unit is “UNPLUGGED” from the wall 

receptacle prior to initial filling or re-filling 

the water tank. 

Never attempt to fill this 

unit under a water tap

always use the 

filling flask provided.

Failure to follow  

these steps will cause the water tank to 

overfill and may pose an electrical safety 

hazard.

6

Using Accessories

To use the nylon detail brushes, attach the 

nylon bristle brush to the end of the angle 

concentrator/brush adapter. (See below.)

CAUTION

: When cleaning 

windows, always avoid any sudden 

changes in temperature to prevent 

glass breakage or cracks.

Please note that the window squeegee can 
only be used with the 
hose. To attach the 
window squeegee to 
the hose, push it in until 
the squeegee locking 
button clicks in place on 
the hose.
Apply steam abundantly, 
rub with the soft spongy end, then remove 
excess water and dirt with the glass wiping 
edge.
This attachment is very useful for cleaning 
large windows, plastic material, ceramic, 
tiled or marble surfaces.

To attach the angle concentrator/brush 

adapter to the hose, hold the hold grip in 

one hand and insert the angle 

concentrator/brush adapter into the nozzle 

end of the hand grip.  Make sure that it 

locks in place. (See below.)

Step 2:

If the floor brush angle adapter 

is not attached to the floor 

brush, hold the brush with its 

bristles up in your left hand. 

With the floor brush angle  

adapter pointing downward, 

insert it into the hole in the back 

of the brush, then turn the floor 

brush angle adapter 180°.

Step 3:

Insert the electrical power cord 

into the wall outlet.  Heating 

time is approximately 6 minutes 

with cold water.  Filling the 

steam generator with hot water 

will shorten heat up time.

Step 1:

Connect one of the extension 

tubes to the hand grip on the 

flexible steam hose.  To 

attach the extension tubes 

one onto the other or 

onto the hand grip, press the 

locking button ensuring that it 

fits into the hole.  (See 

illustrations.)  To disconnect, 

repeat the operation by 

pressing the locking button 

and pulling the two sections 

apart.

Using the Steam Cleaner with 
Floor Brush

Floor Brush

Angle Adapter

NOTE:

Fit floor brush with 

the floor brush 

angle adapter 

on to the 

extension tube. 

Extension Tubes

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS cont.

ATTACHMENTS

How To Assemble & Use

Refilling With Water

Using the Locking Trigger Button

The steam cleaner has a locking trigger 

button. The trigger will lock when you 

have pushed it in all the way. To unlock 

the steam trigger, just press the locking 

trigger button in and the steam trigger 

will pop up, stopping the flow of steam.

Angle Concentrator/Brush Adapter

Step 1: Disconnect electrical power 

cord from wall outlet.

Step 2: Press trigger button until all 

pressure has been released. 

Step 3: Allow the unit to cool for 

approximately 5 minutes 

before refilling with water.

Carefully unscrew safety cap.

Step 4: Slowly pour water using the 

filling flask into the boiler.

DO 

NOT Fill Under a faucet

use 

the filling flask provided. DO 

NOT OVERFILL

Always 

leave approximately 2 1/2 

inches between the top of 

the unit and the water level.

Step 5: Release the locking trigger.

Step 6: Screw safety cap back on the 

appliance and plug appliance 

back into wall outlet. Steam will 

start to be produced as before.

Window Squeegee

5

Reviews: