Shark CN-4000 User Manual Download Page 7

 

 

 

 

Flash 

 

1.2-130 

 

Repairing 12V AGM batteries below 
10

℃ 

(50

Using 12V REPAIR 

This mode is for LEAD-ACID batteries only. It is an advanced battery recovery mode for 
repairing old, idle, stratified or sulfated batteries. NOT all batteries can be recovered. For 
optimal  results,  take  the  battery  through  a  full  charge  cycle,  bringing  the  battery  to  full 
charge, before using this mode. When this mode is chosen, do remember press  Mode button 
for choosing appropriate 12V Mode(s). One REPAIR cycle can take up to 

eight (8) hours 

to 

complete  the  recovery  process  and  will  enter  to  charge  (8  steps  charging  cycle)  when 
completed. This mode uses a high charging voltage and may cause some water loss  in WET 
(flooded) cell batteries. Plus, some batteries and electronics may be sensitive to high charging 
voltages. To minimize risks, disconnect the battery from the vehicle before using this mode. 

 

CHARGING STEPS

 

 

 

STEP 1: DIAGNOSIS 

(Check if battery has connected with the charger and also check 

battery voltage) 

STEP 2: DESULPHATION 

(If battery voltage is too low, programs automatically 

generate pulsing current to remove sulphate, 

up to 5 hours

STEP 3: ANALYSE 

(Check if the battery voltage reaches to the threshold after 

desulphation, and charging begins if the battery voltage is OK) 

STEP 4: SOFT START 

(Charge with echelon constant current) 

STEP 5: BULK 

(Charge with constant maximum current until battery voltage is reached 

Summary of Contents for CN-4000

Page 1: ...0 8A DC Output 12VDC 4A 6VDC 4A Temperature Controlled Please read and understand all important safety and operating instructions before using this charger In addition please read and follow all batt...

Page 2: ...ommended rates of charge 8 Clean battery terminals before connected with the charger Be careful to keep corrosion from coming in contact with eyes 9 When it is necessary to remove a battery from vehic...

Page 3: ...these letters or symbol POS P The negative battery terminal is typically marked by these letters or symbol NEG N 2 Do not make any connections to the carburetor fuel lines or thin metal parts 3 Identi...

Page 4: ...e solid the charging is completed But do NOT break the connection immediately It will automatically switches from full charge to maintenance status without overcharging or damaging the battery 6 It is...

Page 5: ...Circuit 9 Battery Voltage Indicator press hold Mode button for 3 seconds to display the battery s voltage CHARGING MODES CN 4000 has ten modes sel Standby 12V STD 12V COLD 12V AGM 12V AGM COLD 6V STD...

Page 6: ...F EFB batteries Keep on 1 2 130 Charging 12V WET GEL MF EFB batteries below 10 50 Keep on 1 2 130 Charging 12V AGM batteries Keep on 1 2 130 Charging 12V AGM batteries below 10 50 Keep on 1 2 130 Char...

Page 7: ...hen completed This mode uses a high charging voltage and may cause some water loss in WET flooded cell batteries Plus some batteries and electronics may be sensitive to high charging voltages To minim...

Page 8: ...en the battery level is less than 20 When 20 is reached the bar will be solid The 40 bar will slowly flash when the battery level is less than 40 When 40 is reached the bar will be solid The 60 bar wi...

Page 9: ...nty period a product with a defect will be replaced with a new one when the product is returned to the manufacturer The replacement product will be in warranty for the balance of the original two 2 ye...

Reviews: