6
Flash
1.2-130
Repairing 12V AGM batteries below
10
℃
(50
℃
)
Using 12V REPAIR
This mode is for LEAD-ACID batteries only. It is an advanced battery recovery mode for
repairing old, idle, stratified or sulfated batteries. NOT all batteries can be recovered. For
optimal results, take the battery through a full charge cycle, bringing the battery to full
charge, before using this mode. When this mode is chosen, do remember press Mode button
for choosing appropriate 12V Mode(s). One REPAIR cycle can take up to
eight (8) hours
to
complete the recovery process and will enter to charge (8 steps charging cycle) when
completed. This mode uses a high charging voltage and may cause some water loss in WET
(flooded) cell batteries. Plus, some batteries and electronics may be sensitive to high charging
voltages. To minimize risks, disconnect the battery from the vehicle before using this mode.
CHARGING STEPS
STEP 1: DIAGNOSIS
(Check if battery has connected with the charger and also check
battery voltage)
STEP 2: DESULPHATION
(If battery voltage is too low, programs automatically
generate pulsing current to remove sulphate,
up to 5 hours
)
STEP 3: ANALYSE
(Check if the battery voltage reaches to the threshold after
desulphation, and charging begins if the battery voltage is OK)
STEP 4: SOFT START
(Charge with echelon constant current)
STEP 5: BULK
(Charge with constant maximum current until battery voltage is reached