Air Disinfection & Purification Machine (FAST-Y-90A)
23
Maintenance of Purification System
Draw out the purification module, place it in the cleaning area, clean the dust
on the module with air pump and brush, or put it in a special cleaning pool,
and rinse it with warm water mixed with detergent (daily use detergent) at
30°C ~ 40°C.The purification system should be maintained once the unit has
running 4-6 months or more than 4000 hours after last maintenance.
Important Note! Before maintenance, the disinfection module must work
continuously for 2 hours, and the unit maintenance can only be carried out
under the condition of power off.
Note: Water washing mode is adopted. All cleaned modules must be dried
thoroughly before reuse.
Maintenance of Disinfection System
Draw out the disinfection module, place it in a cleaning area, and clean the
dust on the ultraviolet lamp tube with a soft bristle brush or towel; The disin-
fection system should be maintained once the unit has running 4-6 months or
more than 4000 hours after last maintenance.
Important Note! Before maintenance, the disinfection module must work
continuously for 2 hours, and the unit maintenance can only be carried out
under the condition of power off.
The service life of the ultraviolet lamp tube is 10000h. The ultraviolet lamp
tube should be replaced after the service life. Otherwise, the disinfection effect
will be affected.
Note: Please use the original parts and accessories when replacing the UV lamp.
Maintenance of Deodorization System
Draw out the deodorization module and place it in the cleaning area. Use air
pump to clean the dust on the module. The deodorization system should be
maintained once the unit has running 4-6 months or more than 4000 hours
after last maintenance.
The deodorization system shall be replaced after running for 36 months.
Important Note! Before maintenance, the deodorization module must work
continuously for 2 hours, and the unit maintenance can only be carried out
under the condition of power off.
Notes: Please use the original parts and accessories when replacing the de-
odorization module.