SGS Trio OEK-400 User And Maintenance Manual Download Page 10

OPERATION OF THE APPLIANCE

 

10/12

You may adjust heat produced within the device and roasting level of the slices 
accordingly.
by setting commutator position.
During first operation you may smell odor generated within the device, wait for 
approximately 20 minutes, it will diminish.
Place the slices to be roasted on slice feeding panel at the front of the device. Slices 
placed in the panel will slide automatically and start to roast.
Set the outcome direction setter (seen on the installation diagram) to decide on the 
height of the out coming slices. You may get the roasted slices either from front or 
from back.
Turn the switch to “0” position after daily use. Disconnect from the power supply at the 
time relay.
After disconnecting from power supply clean the device up.
It  is recommended to operate the device between temperatures of -5ºC +40ºC and in 
ambient humidity of maximum 65%.

This part shows toast position of the bread

 

                           

OPERATION OF THE DEVICE:

       Conveyor toaster is used in kitchens of restaurants, fast food stands, canteens, 

hospitals in order to Roast bread.

Before initial use of the device, the outer surface should be wiped with a cloth soaked 

in warm water and soap. 

NOTE:  Do not use except purpose of use. The device should be operated by 

qualified personnel knowing safety terms and technical specifications and 
who has read the instruction manual.

1. Take the conveyor toaster out of its packing carefully.
2. Plug the power cable to power connection with grounding.
3. Turn the commutator on to operate the machine.

1

3

2

Heater power control switch
1-Low toast
2-Middle toast
3-High toast

Summary of Contents for Trio OEK-400

Page 1: ...PRODUCTION YEAR SERIAL NO 2009 Published on 23 01 2004 VER V11 7 Page1 of 12 CONVEYOR TOASTER OEK 400 USER S AND MAINTENANCE MANUAL 1 2...

Page 2: ...ARNING SIGNS 6 SAFETY DETAILS 7 TRANSPORTING AND MOVING 8 9 INSTALLATION OF THE DEVICE AND ELECTRICAL CIRCUIT DIAGRAM 10 11 OPERATION OF THE DEVICE 12 TERMS OF GUARANTEE 2 12 CAUTION This device shoul...

Page 3: ...r you don t have enough information please get in touch with authorized service by phone Please keep in mind that if the service personnel is delayed at your site related expenses and delay costs will...

Page 4: ...TRICAL INPUT kW 1 9 SUPPLY VOLTAGE VAC 220 240 WORKING FREQUENCY Hz 50 60 POWER SUPPLY CABLE Number of cores x mm 3x1 5 DIMENSIONS Width Length Height mm 440x400x340 BENCH HEIGHT mm 850 MAXIMUM SLOPE...

Page 5: ...WARNING SIGNS POWER NETWORK GROUNDING PE GROUNDING OVERHEAT SUPPLY CONNECTION MONOPHASE GROUNDED POWER 5 12 VOLTAGE 220 240V NPE 50 60 Hz...

Page 6: ...ot be handled by anyone else except for the manufacturer or authorized service 6 12 The device should not be exposed to direct air flow 5 C 40 C Supply voltage of the device is 220 240V 50 Hz Do not u...

Page 7: ...m the power supply The vehicle can be moved with manpower Do not hit or drop the device when moving 7 12 1 2 Machines installed by an authorized service CANNOT BE MOVED ELSEWHERE ITS POWER SUPPLY CABL...

Page 8: ...nds should be adjustable and leveled with balance Power connections should be checked by an eligible electrician and the device should be connected to a fuse at 400 mm high above the ground Power inst...

Page 9: ...RCUIT DIAGRAM 9 12 S1 Commutator S2 Rate setting button BTH Upper resistance TH Lower resistance M1 Motor M2 Fan S1 Commutator S2 Rate Setting Button RA Lower Resistance RU Upper Resistance M1 Motor M...

Page 10: ...e time relay After disconnecting from power supply clean the device up It is recommended to operate the device between temperatures of 5 C 40 C and in ambient humidity of maximum 65 This part shows to...

Page 11: ...oes not operate after those checks call your authorized service dealer LIFE OF USE Devices life of use is 10 year if it is used under recommended conditions CLEAN UP AND MAINTENANCE Clean up and maint...

Page 12: ...on about the kind and the type of the device serial numbers printed on the guarantee document are scraped rubbed or changed then the guarantee is not valid 6 The guarantee covers only maintenance and...

Reviews: