PREPARATION FOR STARTING

5. Keep the oil level in the red
circle of the oil glass sight win-
dow.
You can purchase compressor oil
from our website at:
www.sgs-engineering.com

6.

 

Open the 

drain cock

, set

 

the power switch knob to posi-
tion “on” and let the compres-
sor run for 10 minutes with

 

no 

load to ensure the moving

 

parts are lubricated before

 

regular service.

1. The compressor is controlled by a pressure switch. It can be

stopped automatically as the pressure increases to the maximum
and restarted as pressure decreases to the minimum. The rated
pressure has been adjusted during the manufacturing process
- don’t alter it carelessly. As soon as the motor is switched off
the compressed air in the discharge pipe should be released
through the release valve under the switch. This is a necessary
condition before restarting or the motor will be damaged. The
rated pressure can be altered by turning the adjusting screw.

OPERATION AND ADJUSTMENT

WWW.SGS-ENGINEERING.COM

Summary of Contents for SC24H

Page 1: ...FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE OWNER S MANUAL SC24H SC50H AIR COMPRESSOR...

Page 2: ...Filter 1 3 Breather Pipe 1 4 Wheel 2 5 Wheel Axis 2 6 Rubber Gasket 1 or 2 7 Instruction Manual 1 ITEM DATA Model SC24H SC50H Power 1 5 kW 2 5 HP Voltage 230 V Frequency 50 Hz Motor Poles 2 P Rated Sp...

Page 3: ...ns DRESS PROPERLY Loose clothing or jewellery may be caught in moving parts Always tie long hair back and wear suitable clothing SAFETY PRECAUTIONS WARNING SYMBOLS READ THIS INSTRUCTION MANUAL CARE FU...

Page 4: ...SAFETY PRECAUTIONS KEEP VISITORS CHILDREN AWAY Do not allow visitors children to han dle the air compressor or attachments and ensure that any people in the work area are suitably dressed KEEP THE WO...

Page 5: ...S ENGINEERING COM PREPARATION FOR STARTING 1 Check all nuts and bolts Make sure all loosened parts are tightened before starting 2 Before running the compres sor remove the white plug and connect the...

Page 6: ...r is controlled by a pressure switch It can be stopped automatically as the pressure increases to the maximum and restarted as pressure decreases to the minimum The rated pressure has been adjusted du...

Page 7: ...he output pressure of compressed air can be adjusted by the regulat ing valve Grip the regula tion valve knob and turn it clockwise to increase the pressure OPERATION AND ADJUSTMENT 3 When the running...

Page 8: ...thick ness is not less than 2 1mm MAINTENANCE 2 PARTS LIST ITEM PART QTY 1 Bolt M8x110 4 2 Cylinder head 1 3 Cylinder head gasket 1 4 Valve plate 1 5 Valve gasket 1 6 Cylinder 1 7 Cylinder gasket 1 8...

Page 9: ...or will overheat If it cuts out this is a safety feature to protect you and your compressor Leave this compressor for a good while until you reset it If the compressor turns off again on re set you sh...

Page 10: ...d cylinder worn or damaged 1 Keep the level within set range 2 Check and clean 3 Repair or replace CE MARK SGS ENGINEERING IS COMMITTED TO DESIGNING MANUFACTURING AND MARKETING PRODUCTS THAT MEET OR E...

Page 11: ...t Company Secretary Derby UK 24th JUNE 2015 SGS Engineering UK Ltd SGS Engineering UK Ltd 2 West Side Park Raynesway Derby DE21 7AZ Air compressor SC24H SC50H EN 1012 1 2010 AfPS GS 2014 01 PAK Machin...