Page 1: ......

Page 2: ...ME 1200 1 MK 1200 D MD 1200 1 ME 1200 2 ...

Page 3: ...ICIAL SPECIFICATIONS 7 8 ELECTRIC SCHEME 9 WARNING SIGNS 10 11 PRODUCT LABEL INFORMATION 12 SAFETY WITH DETAILS 13 HANDLING AND RELOCATION 14 20 USING THE DEVICE CLEANING AND MAINTENANCE 21 WARRANTY CONDITIONS 22 25 EXPLODED VIEW SPARE PART LIST 26 CE DECLARATION 3 ...

Page 4: ...e to point you understand that you and your nearest you want information from an authorized phone service If the stand of costs and service personnel called for Assembly Keep in mind that for every hour waiting fee will be billed to you We hope you get the most out of our product Hi there We thank you for your confidence in choosing our device and our company Our devices are used in 60 countries a...

Page 5: ... 60 50 60 THERMOSTAT RANGE ºC 50 400 50 400 50 400 50 400 POWER CORD mm H07 RNFR 5 x 6 5 x 6 5 x 6 5 x 4 PROTECTION CLASS IP 20 IP 20 IP 20 IP 20 NET WEIGHT KG 498 with Steam System 543kg 383 with Steam System 413kg 355 with Steam System 385kg 130 with Steam System 145kg RATED CURRENT A 100 75 50 25 INSULATION ROCK WOOL ROCK WOOL ROCK WOOL ROCK WOOL COOKING STONE FIRECLAY STONE FIRECLAY STONE FIRE...

Page 6: ...0 POWER CORD mm H07 RNFR 5 x 10 5 x 6 5 x 6 5 x 4 5 x 4 PROTECTION CLASS IP 20 IP 20 IP 20 IP 20 IP 20 NET WEIGHT KG 660 with Steam System 727 5kg Fullstone 810kg 505 with Steam System 550kg Fullstone 605kg 455 with Steam System 500kg Fullstone 555kg 290 with Steam System 312 5kg Fullstone 340kg 170 with Steam System 192 5kg Fullstone 220kg RATED CURRENT A 121 89 64 32 32 INSULATION ROCK WOOL ROCK...

Page 7: ...STRAIGHT POWER SCHEME 7 ...

Page 8: ...STEAM ELECTRIC SCHEME 8 ...

Page 9: ...ETWORK PROTECTION GROUNDING HIGH TEMPERATURE ELECTRICAL CONNECTION VALUES 380V 400V 50 60 Hz ELECTRICITY WARNING SIGNS PE Voltage 380 V 400 V Network Access 380 400 V 3 NPE Terrestrial Trunked Frequency 50 60Hz 9 ...

Page 10: ...PRODUCT LABEL INFORMATION 10 ...

Page 11: ...PRODUCT LABEL INFORMATION 11 ...

Page 12: ... flames flare if any to use the fire extinguishers closing the gas valve and power switch Never use water to extinguish the flames The device operating voltage 380 V 400 V 380 400 V 3 NPA 50 60 it is Hz Do not use a power supply voltage other than that Electrical connections to supply insurance against the danger of leakage current of 30 mA leakage current must be performed by placing insurance If...

Page 13: ...nguishers closing the gas valve and power switch Never use water to extinguish the flames a wall of the device compartment kitchen furniture to be positioned close to the decorative covering VB N if their coating is made from fireproof material or a suitable non combustible heat insulating material the distance of 5 cm otherwise must be at least 20 cm It is recommended attention to obey the rules ...

Page 14: ... between 1 and 60 minutes and keys can be done with If the increase and decrease buttons are held down for 3 seconds increases or decreases the value quickly the values shown in displey will be automatically stored Time LED flashes once per second when the time counting begins 3 UPPER FRONT UPPER AND LOWER HEATING BACK SET DISPLAY LED AND ADJUSTMENT KEYS Heating up the set with the arrow keys to e...

Page 15: ... reached 7 START STOP KEY AND LED LEDs light when pressed and switches to position START Depending on the appliance starts to control temperature setpoint Turbo automatically activated when the measured temperature is below the set value resistors full works setpoints are changed when the start position According to the new setpoint temperature control set will continue to run Measured temperature...

Page 16: ...dicator Pr 1 writer Auction Set temperature decrease key parameter value is set to help If no adjustments are made within 10 seconds the device will automatically exit from the menu Set Time press the Up button to save the set parameter values to memory Indicator does no flash remains solid To set the parameter value by pressing the key again the next time Sets Auction the parameter value starts t...

Page 17: ...ed to be engaged in the resistance Pr 5 The device is powered up on location The temperature is measured from the time off until the temperature is above the set value with this parameter the cooling fan is consistently enforced Pr 6 Buzzer is determined whether or not the device in its active buzzer sound Parameters 1 is set at the buzzer to buzzer is activated 0 is set passive Örnek Çalışma Hidd...

Page 18: ...mittent buzzer and siren relay pull releases All controls remain disabled Failure resolved until the system fails When the fault corrected setting must be done again Er 2 Oven temperature rises above the temperature indicator 400ºc n Er 2 writer On the other intermittent buzzer and siren relay pull releases All controls remain disabled Failure resolved until the system fails When the fault correct...

Page 19: ... cooking pizza and you get pizza Close the lid again Although your cutting power to the furnace in order to save on a short waiting time during use the thermostat take hold bringing to 90 C If the oven s power is cut off due to the cold to go to a sufficient temperature for the next cooking process will result in a loss of time and energy After daily use turn off the power switch Do the cleaning o...

Page 20: ...ven these Authorized Service of EXCEPT FOR A TECHNICAL STAFF MEMBER OR incompetent THE UNIT INTERVENTION DEVICE WARRANTY WILL REMAIN OUTSIDE SO THE UNAUTHORIZED PERSONS ABSOLUTELY NOT ALLOW THE DEVICE DO NOT INTERVENE THESE CONDITIONS SHALL BE LIABLE FOR ANY WAY MANUFACTURING COMPANY Our AUTHORIZED SERVICE DURING SERVICE ORIGINAL SPARE PARTS WITHOUT ANY REASON OFFER CAN NOT USE IN ANY WAY THIS IS ...

Page 21: ...as well as in case of failure due to installation errors labor costs the cost of parts replaced or under any other name without demanding any fee will be repaired 5 Although we use the right consumer goods repair From the date of delivery to engaging in as to stay within the warranty period in a year at least four times or manufacturer producer and or failed six times in addition to the warranty p...