SG
Owners Manual
MODELS: Breeze 320 - Breeze 540 - Breeze 760
Residential Systems
Page 1: ...SG Owners Manual MODELS Breeze 320 Breeze 540 Breeze 760 Residential Systems...
Page 2: ...ranty 6 Pool water must be tested regularly in order to properly maintain its chemical balance Problems or equipment failures resulting from the failure to maintain pool water chemistry in accordance...
Page 3: ...Add It 9 Salt Table 10 Chlorinator Installation 11 Installation Preparation 12 Procedures for Installation 13 Special Situations 14 Start up procedures 14 System operation 15 Control Center Functions...
Page 4: ...n if you cannot verify the receptacle is protected by a GFCI 4 Do not bury cord Locate cord to minimize abuse from lawn mowers hedge trimmers and other equipment 5 WARNING To reduce the risk of electr...
Page 5: ...r protection CHEMICAL USE HAZARD To avoid personal injury when working with pool chemicals always wear rubber gloves and eye protection and work in a well ventilated area Use caution when choosing a l...
Page 6: ...g or removing the Electrolytic cell Your pump filter is operated under pressure and the pressure must be released before you begin work Please see your pump filter owner s manual for further instructi...
Page 7: ...portant aspect of maintaining a swimming pool Pool water must be tested regularly in order to properly maintain its chemical balance In accordance with The Association of Pool and Spas Professionals A...
Page 8: ...til the reading taken at least 24 hours later is in the 80 100 PPM range When TA is correct you may need to adjust pH Use Chlorine Stabilizer to Protect Chlorine Residual Chlorine stabilizer also know...
Page 9: ...dirty cell see illustration 5 on page 15 and Troubleshooting section for instructions on what to do when the system goes into service mode We recommend using pool salt which can be purchased at pool a...
Page 10: ...293 330 367 403 440 477 513 550 587 523 660 697 733 2000 133 166 200 234 267 300 333 367 400 433 467 500 533 567 600 633 667 2200 120 150 180 210 240 270 300 330 360 390 420 450 480 510 540 570 600 24...
Page 11: ...ing Bracket 1 Cleaning Stick Acid Replacement Device 1 Owner s Manual The following tools will be required to install the Breeze system Screwdriver Level Hacksaw or PVC cutter Wire Stripping Tool Elec...
Page 12: ...if necessary can be reduced to 1 inch PVC The cell has a 15 foot power cord and cannot be modified use caution to place the cell housing within reach of the cell cord The Breeze Control Center is shi...
Page 13: ...uitable location for the mounting of the Control Center The Control Center must be mounted on a noncombustible surface 2 The wall mounting bracket should be fastened to the wall at a height comfortabl...
Page 14: ...d for cleaning when necessary START UP PROCEDURES 1 Balance your water chemistry according to the Water Chemistry Parameters shown on page 7 Add the proper amount of salt and circulate 24 hours before...
Page 15: ...n the cell blades Chlorine production and scale buildup are easily visually monitored through the SG clear cell housing Control Center Functions 1 Sanitizer Output Lights shows level of chlorine outpu...
Page 16: ...emely high bather load Unlike other chlorinators the Breeze is able to produce chlorine at all settings on the Sanitizer Output scale for the entire run time Adjusting the Output control from 75 down...
Page 17: ...des and the legs that attach the electrodes to the cell base illustration 4 below If there is no buildup there is no need to clean the cell If there is buildup ALWAYS TURN OFF THE PUMP PRIOR TO CLEANI...
Page 18: ...esh water A build up of byproducts can damage the electrolytic cell Monthly Service To ensure that the correct chemical balance is maintained in your pool it is important to perform the following reco...
Page 19: ...ect the calcium hardness or total alkalinity levels Maintain and balance only as needed CYANURIC ACID STABILIZER CONDITIONER This chemical CYA or Cyanuric Acid allows your chlorine residual to last lo...
Page 20: ...ight is yellow solid Increase Salt level by adding salt according to chart on Page 10 High nitrate level Contact Pool Professional Metals present in pool water Contact Pool Professional New pool water...
Page 21: ...Part C on Illustration 2 page 13 on bottom of Control Center if tripped press rubber cover to reset No AC power to Control Center Verify time clock is providing 220 VAC to Control Center when active...
Page 22: ...oot For Breaker 1 8 PC114 D2 10 Circuit Breaker 1 9 PC123 D 2 1 Control Center Label 1 10 PC133 D1 10 Primary Terminal Block 1 11 PC104 C3 2 Acrylic Cover 1 12 PC105 C3 5 On Off Switch 1 13 PK6101 D03...
Page 23: ...evaluated for best results Where heightened chlorine demand exists due to warmer climates humidity high bather load water features and other environmental factors the maximum pool size should be reduc...
Page 24: ...Date Control Center Serial Model Number Factory Direct Customer Assistance Tech Support Hotline 1 866 972 SALT 7258 or 1 480 385 3052 FAX 1 480 557 0099 Email to customersupport sgschlorinators com Re...