background image

10

Preparing for installation

Unpack the device and inspect it to ensure that it has not been damaged during transport.

The Q-7 series is shipped with two quarter-turn brackets, that can be used to mount the device at elevation, and a W-
DMX

TM

 G4 wireless antenna.

The fixture has an ingress protection rating of IP65, and is designed for use in wet locations. This means that it is  
protected from:

Dust, to the degree that dust cannot enter the device in sufficient quantities as to interfere with its operation. 

Lower pressure jets of water from any direction. 

When selecting a location for the device, ensure that:

It is situated away from public thoroughfares and protected from contact with people.

It is not immersed in water or exposed to high-pressure water jets.

It has adequate ventilation.

Manual_Q7-Q7W_Rev.2_170x113,3.book  Page 10  Thursday, May 22, 2014  12:38 PM

Summary of Contents for Q?7

Page 1: ...Q 7 Q 7 WHITE Manual_Q7 Q7W_Rev 2_170x113 3 book Page 1 Thursday May 22 2014 12 38 PM...

Page 2: ...7 3 in 437 17 2 in 497 19 6 in 456 17 9 in 212 8 3 in 312 12 3 in 268 10 6 in 185 7 3 in 122 4 8 in 90 3 5 in 90 90 Measurements in millimetres and inches in brackets Drawing not to scale Manual_Q7 Q...

Page 3: ...tion contained in this manual The SGM logo the SGM name and all other trademarks in this document pertaining to services or products by SGM or its affiliates and subsidiaries are trademarks owned or l...

Page 4: ...power 13 Configuring the device 14 Setting a static color manually 15 Using stand alone operation 16 Connecting to a DMX control device 17 Configuring the device for DMX control 18 Device personality...

Page 5: ...5 Control menu 26 Specifications 32 User s notes 37 Manual_Q7 Q7W_Rev 2_170x113 3 book Page 5 Thursday May 22 2014 12 38 PM...

Page 6: ...t and the hazards involved Preventing electric shock Always power off unplug the device before removing any covers Ensure that the power is turned off when connecting the device to the AC mains supply...

Page 7: ...re a minimum clearance of 0 1 m 4 in around the cooling fans Do not paint cover or modify the device Keep all flammable materials away from the device Allow the device to cool for 15 minutes after ope...

Page 8: ...load bearing surface with suitable corrosion resistent hardware For temporary installation with clamps ensure that the quarter turn fasteners are turned fully and secured with a suitable safety cable...

Page 9: ...GB color mixing Q 7 color temperature control a half peak spread angle of 110 and a lamp life expectancy of 50 000 hours A Q 7 1 000 RGB 1 000 White LEDs A Q 7W 1 000 White LEDs B Base C Safety wire e...

Page 10: ...for use in wet locations This means that it is protected from Dust to the degree that dust cannot enter the device in sufficient quantities as to interfere with its operation Lower pressure jets of wa...

Page 11: ...te However in locations with high rainfall you may wish to fabricate a rain shield above the device or modify the Q 7 s position and orientation to minimize pooling For permanent installation on the g...

Page 12: ...rackets and suitable clamps WARNING Always secure an elevated Q 7 with a safety cable as backup The device can be tilted from 0 180 degrees To adjust the tilt angle loosen the two tilt screws one on e...

Page 13: ...use The power cable color coding is given in the table Connect the black wire to live Connect the white wire to neutral Connect the green yellow wire to ground earth The device must be grounded earthe...

Page 14: ...formation A Operational mode Quick color stand alone or DMX mode B DMX address C External data indicator if DMX control is active D External data protocol W DMX or DMX The fixture is set by default to...

Page 15: ...r menus see Control menu on page 26 Note that whenever the Manual Quick color settings are changed the fixture will be set by default to automatically start in quick color mode whenever it is powered...

Page 16: ...e in time for the transition from one color or white to the next and a wait static time each of up to 999 minutes and 59 seconds in duration To program a stand alone program use the Manual Editor menu...

Page 17: ...een established W DMXTM G4 operates at a frequency of 2 4 GHz so ensure that the DMX transmitter is configured to operate in this range The device is controllable using a DMX control device and it can...

Page 18: ...e Q 7 can be controlled using signals sent by a DMX controller on a number of channels which varies depending on the DMX mode that has been set The first channel used to receive data from a DMX contro...

Page 19: ...l specify the DMX mode that provides the device controls that you require DMX mode Function 4 Individual control of color channels for red green blue white RGBW 6 RGBW Shutter and Intensity 8 XC5 Emul...

Page 20: ...wn it might be a useful to flip the screen so that it is easy to read To flip the display use the Settings Flip display menu or press the up and down buttons on the control panel at the same time Sett...

Page 21: ...le available from your SGM distributor Cleaning To obtain optimal performance regular cleaning is essential Cleaning schedules will vary greatly depending on the operating environment and the installa...

Page 22: ...page 24 Q 7 DMX protocols Q 7 4 channel mode Channel Name DMX value Description Info Default DMX value Fader type 1 RED 0 255 No RED Maximum RED 0 Fade 2 GREEN 0 255 No GREEN Maximum GREEN 0 Fade 3 BL...

Page 23: ...Slow Fast 176 199 Pulse Close Slow Fast 200 244 Strobe Random Slow Fast 245 255 Open 2 INTENSITY 0 255 No light Maximum light 0 Fade 3 RED 0 255 No RED Maximum RED 0 Fade 4 GREEN 0 255 No GREEN Maximu...

Page 24: ...efault DMX value Fader type 1 Panel 1 0 255 No LIGHT Maximum LIGHT 0 Fade 2 Panel 2 0 255 No LIGHT Maximum LIGHT 0 Fade 3 Panel 3 0 255 No LIGHT Maximum LIGHT 0 Fade 4 Panel 4 0 255 No LIGHT Maximum L...

Page 25: ...st 176 199 Pulse Close Slow Fast 200 244 Strobe Random Fast Slow 245 255 Open 2 INTENSITY 0 255 No LIGHT Maximum LIGHT 0 Fade 3 Panel 1 0 255 No LIGHT Maximum LIGHT 0 Fade 4 Panel 2 0 255 No LIGHT Max...

Page 26: ...fixture serial number RDM ID Displays the fixture RDM ID for use with the SGM Tool app DMX View Displays received DMX levels Temperatures Mainboard Displays temperature on main circuit board LED Panel...

Page 27: ...urve Linear Provides equal resolution dimming from 0 to 100 Gamma Corrected Provides high resolution dimming at low levels Flip Display Disable Selects normal control panel display Enable Flips contro...

Page 28: ...ust default minimum setting 0 1000 Min green Q 7 Min blue Q 7 Min white Q 7 Min panel 1 Q 7W Min panel 2 Q 7W Min panel 3 Q 7W Min panel 4 Q 7W Factory default Reset the fixture to factory default set...

Page 29: ...2200 K Q 7W Static quick color white temperature 2200 K mix 0 255 Sets fixture to quick color startup mode 3000 K Q 7W Static quick color white temperature 3000 K mix 0 255 Sets fixture to quick colo...

Page 30: ...cted scene 0 255 2200 K Q 7W 2200 K white temperature value in currently selected scene 0 255 3000 K Q 7W 3000 K white temperature value in currently selected scene 0 255 4000 K Q 7W 4000 K white temp...

Page 31: ...e Close 200 244 Variable Random Strobe 245 255 Shutter Open Test Off Stops test sequence execution Automated test Initiates a self test sequence Burn In test 30 min Service use only Display test Servi...

Page 32: ...xpected lifetime 50 000 hours Beam angle 110 fixed INSTALLATION Orientation Any Rigging possibilities Stand bracket included or hanging Omega clamps included Safety features Bottom mount for safety wi...

Page 33: ...ing and addressing Wireless DMX RDM Stand alone mode programmable by RFID OLED graphical display 5 buttons Software upgradable via Uploader cable DMX channels 4 or 6 ELECTRICAL AC power nominal 208 25...

Page 34: ...umen blue 19 000 lumen white Efficacy 60 lm W CRI Min 80 FUSES Main fuse not user replaceable T5A INCLUDED ITEMS Included items Floor stand incl screws 2 pcs Omega clamps Wireless DMX G4 antenna User...

Page 35: ...er no 80030525 Q 7 White Brackets Order no 83060603 BCC 2 dual bracket Brackets Order no 83060604 BCC 4 quad bracket Cables Order no 83062011 SGM USB uploader cable Flight case Order no 82051501 Fligh...

Page 36: ...rms to 2004 108 EC EMC Directive Conforms to 2006 95 EC Low Voltage Directive Conforms to 2011 65 EU RoHS2 Directive Specifications subject to change without notice Manual_Q7 Q7W_Rev 2_170x113 3 book...

Page 37: ...37 User s notes Manual_Q7 Q7W_Rev 2_170x113 3 book Page 37 Thursday May 22 2014 12 38 PM...

Page 38: ...38 Manual_Q7 Q7W_Rev 2_170x113 3 book Page 38 Thursday May 22 2014 12 38 PM...

Page 39: ...39 Manual_Q7 Q7W_Rev 2_170x113 3 book Page 39 Thursday May 22 2014 12 38 PM...

Page 40: ...SGM A S Sommervej 23 8210 Aarhus V Denmark Tel 45 70 20 74 00 info sgmlight com www sgmlight com Manual_Q7 Q7W_Rev 2_170x113 3 book Page 40 Thursday May 22 2014 12 38 PM...

Reviews: