![SGB DLR-G Documentation Download Page 9](http://html1.mh-extra.com/html/sgb/dlr-g/dlr-g_documentation_1251035009.webp)
24/10/2018
PRESSURE LEAK DETECTOR
DLR-G ..
- 9 -
3. Technical Data of the Leak Detector
3.1
General Data
Dimensions and drilling pattern:
see sections 12.3 and 12.4
Weight:
2.1 kg (plastic housing)
6.3 kg (stainless steel housing)
Storage temperature range:
-40°C to +70°C
Operating temperature range:
0°C to +50°C (plastic housing)
-40°C to +60°C (stainless steel
housing)
Housing protection class:
IP 30 (plastic housing)
IP 54 (stainless steel housing)
3.2
Electrical Data
Power supply
100
… 240 V AC
optional:
24 V DC
Power input:
10 W (without heating)
28
W (incl. heating at 20°C)
Terminals 5, 6 (external signal):
max. 24 V DC; max. 300 mA*
Terminals 11…13 (voltage-free):
DC ≤ 25 W or AC ≤ 50 VA
Terminals 17…19 (voltage-free):
DC ≤ 25 W or AC ≤ 50 VA
Fuse protection:
max. 10 A
Overvoltage category:
2
* With Ethernet board max. 150 mA
Technical Data