1Ch: wrong notepad page number;
1Dh: fail to operate the communication port;
others: system reserved;
VI Module Instruction System
R303A series provide 23 instructions. Through combination of different instructions, application
program may realize muti finger authentication functions. All commands/data are transferred in
package format.
Refer to 5.1 for the detailed information of package.
System-related instructions
Verify passwoard VfyPwd
Description: Verify Module’s handshaking password. (Refer to 4.6 for details)
Input Parameter: PassWord (4 bytes)
Return Parameter: Confirmation code (1 byte)
Instruction code: 13H
Command (or instruction) package format:
2 bytes
4bytes
1 byte
2 bytes
1 byte
4 byte
2 bytes
Header Module
address
Package
identifier
Instruction
code
Password Checksum
0xEF01 xxxx
01H
07H
13H
PassWord
sum
Acknowledge
package
format:
2 bytes
4bytes
1 byte
2 bytes
1 byte
2 bytes
Header Module
address Package
identifier
Package
Length
Confirmation
code
Checksum
0xEF01 xxxx 07H 03H xxH sum
Note: Confirmation code = 00H: Correct password;
Confirmation code = 01H: error when receiving package;
Confirmation code = 13H: Wrong password;
Set password SetPwd
Description: Set Module’s handshaking password. (Refer to 4.6 for details)
Input Parameter: PassWord (4 bytes)
Return Parameter: Confirmation code (1 byte)
Instruction code: 12H
Command (or instruction) package format:
2 bytes
4bytes
1 byte
2 bytes
1 byte
4 byte
2 bytes
Header Module
address
Package
identifier
Package
length
Instruction
code
Password Checksum
0xEF01 xxxx
01H
07H
12H
PassWord
sum
- 8 -
Summary of Contents for R303A Series
Page 24: ...22...