Installer Setup
Deadband Settings
The Deadband is the number of degrees or minutes that the thermostat waits
before it initiates the stages of heating or cooling.
1st Stage Deadband (setup step 23) - Specifies the minimum temperature
difference between the room temperature and the desired setpoint before
the first stage of heating or cooling is allowed to turn on. (1 - 6 degrees) For
example, if the heat setpoint is 68˚ and the 1st Stage deadband is set to 2
degrees, the room temperature will need to reach 66˚ before the heat turns on.
Fahrenheit or Celsius
(setup step 24)
This feature allows the thermostat to display temperature in Fahrenheit or
Celsius.
Press Fan To Clear All Messages
(setup step 37)
This feature allows the user to clear all current error messages from the display.