21
9-5. Environmental Requirements
Operating
Temperature 5°C to 40°C
Humidity
10% to 90% RH (without condensation)
Transport/
Storage
(except paper)
Temperature -20°C to 60°C
Humidity
10% to 90% RH (without condensation)
9-6. Reliability
MCBF
60 million lines
TPH Life
160Km
Cutter Life
1.5 million cuttings
(If the paper thickness is between 65 and 90µm)
9-7. Certification
1
CE
2
FCC
3
KC
4
UL/cUL
5
ENERGY STAR
This equipment is indoor use and all the communication wiring are
limited to inside of the building.