3-5-2. Key Operation
Make Weight value as Zero.
Under F08, you can set the Zero key operation range, as 2%, or 5%, or 10%, or 20% of
Max. Capacity.
※
Under “Tare” key input, Zero key will not be activated.
Make Weight value as Zero, including Tare Weight.
Under F09, you can set the Tare key operation range, as 10%, 20%, 50%, or 100% of
Max. Capacity.
Tare setting : Under F10-00 setting, “TARE” key input
Under F10-01 setting, “Tare”+ No. key + “Enter”
Remove set TARE value.
Under Packer Mode(F21-02), Start the packer mode process.
First input is “START”, Second input is “STOP”
Manual “Unit Weight” input Key.
If you already knew the “Unit Weight”, you can input “Unit weight” without calibration.
You can set each weighing process as a certain P/N.
Each weighing process will be saved with FINAL, PRE1, PRE2, and Free Fall set
value.(Max. 50 kinds of P/N you can set)
And you can call certain P/N with each set value.
You can set SP1 value through this key.
You can set SP2 value through this key.