166
Operating Instructions – MOVIGEAR® SNI-B
8
Description of power section parameters
Parameters
8.6.7
Control functions
Power section parameters \ control functions \ brake functions
Deactivate
DynaStop
®
with-
out enable signal
index 8893.0
This parameter is used to set the function "Deactivate DynaStop
®
without enable sig-
nal":
• 0 = NO
• 1 = YES
When the function is set to YES, DynaStop
®
can be deactivated also without a drive en-
able signal.
Brake function
index 8584.0
This function gives users the option to choose between electrically holding the load and
activating DynaStop
®
in hold status.
The parameter defines whether DynaStop
®
is activated or not when the enable signal is
withdrawn (enable = "0").
• 0 = OFF: The drive decelerates along the set ramp. When the speed is "0",
DynaStop
®
is not activated, and the drive generates a holding torque.
• 1 = ON: The drive decelerates along the set ramp. When the speed is "0", DynaStop
®
is activated.
INFORMATION
For more information about deactivating DynaStop
®
without drive enable signal, refer
to chapter "Operation".
INFORMATION
DynaStop is
always
activated when /CONTROL.INHIBIT = 0.