Setpoints/ramp generators
Power section parameters \ setpoints/ramp generators \ setpoint monitoring
Setpoint filter
index 8468.0
The speed ramp is filtered. The filter can be used for dampening stepped setpoint
selections, e.g. from external controllers or interference pulses at the analog input.
• Setting range: T = 0 – 5 – 3000 ms (0 = setpoint filter off)
Setpoint stop func-
tion index 8578.0;
stop setpoint
index 8579.0; start
offset index 8580.0
If the setpoint stop function is activated, the inverter is enabled when the speed setpoint
is larger than the stop se start offset.
Inverter enable is revoked when the speed setpoint falls below the stop setpoint.
9007201855384331
t
T
63%
V
e
0
0
T
t
37%
0
0
Setpoint step change
Step response
U
Setpoint step change
Step response
U
9007201855386251
Start setpoint
Speed
setpoint
Integrator
setpoint
Stop setpoint
Start offset
00