Technical data of THM20E
Technical Data
Pick-up character-
istic curves
The following characteristic curves show the transmittable power P
4
of the pick-up
against the following values:
• Ambient temperature
ϑ
[°C]
• Time under load t [s]
• Line cable current I
L
[A]
• Line cable distance x [mm]
• Temperature rise factor k
1
Transmittable
power at I
L
= 60 A,
x = 10 mm
The following figure shows the transmittable power for the following values:
• Line cable current I
L
= 60 A
• Line cable distance x = 10 mm
INFORMATION
• The first inflection point of the characteristic curve occurs at a pick-up temperature
ϑ
K
of 65 °C. From this point on, the pick-up power P
4
decreases with increasing
pick-up temperature
ϑ
K
almost linearly with the pick-up temperature
ϑ
K
.
• The second inflection point of the characteristic curves occurs at the maximum
pick-up temperature
ϑ
K
of 85 °C. At this temperature, the maximum continuous
power P
2
is reached at the corresponding ambient temperature. The temperature
rise factor k
1
determines the magnitude of the temperature rise
∆ϑ
compared to the
ambient temperature
ϑ
, based on the transmitted continuous power P
2
.
• The temperature values
ϑ
in the characteristic curves refer to installation condition
E
1
(
→
chapter "Notes on pick-up characteristic curves" (page 33)).
2714152203
[1]
ϑ
= 20 °C / k1 = 32
[2]
ϑ
= 30 °C / k1 = 29.4
[3]
ϑ
= 45 °C / k1 = 32.6
500
1000
1500
2000
2500
3000
0
400
800
1200
1600
2000
2400
2800
3200
[1]
[3]
[2]
P
4
[W]
t[s]
P
i
f
kVA
Hz
n