5
NF line filter
Technical data
Manual – Accessories
20
5.2.2
IP20/IP66, 3 x 220 – 500 V, 6 – 300 A
Type
Unit
NF LT 006 503-20
NF LT 016 503-20
NF LT 025 503-20
Part number
18411045
18411053
18411061
Nominal voltage U
N
(in accord-
ance with EN 50160)
V
3 x AC 220 – 480, 48 – 62 Hz
Rated current I
N
A
6
16
25
Leakage current I
mA
< 10
< 35
< 35
Operating temperature
°C
-25 to +40
Degree of protection
IP20
Mass
kg
1.58
2.5
2.7
Assignment for LTE-B:
AC 230 V
AC 400 V
0004/0008
0015 – 0022
0040
0008/0015
0022 – 0055
0075
Assignment for LTP-B:
AC 230 V
AC 400 V
0008
0015 – 0030
0040/0055
0008 – 0022
0040/0055
0075/0110
UL/cUL approval
No
No
No
Type
Unit
NF LT 006 503-66
NF LT 016 503-66
NF LT 025 503-66
Part number
18411150
18411169
18411177
Nominal voltage U
N
(in accord-
ance with EN 50160)
V
3 x AC 220 – 480, 48 – 62 Hz
Rated current I
N
A
6
16
25
Leakage current I
mA
< 10
< 35
< 35
Operating temperature
°C
-25 to +40
Degree of protection
IP66
Mass
kg
1.6
2.5
2.7
Assignment for LTE-B: AC 230 V
AC 400 V
0004/0008
0015 – 0022
0040
0008/0015
0022 – 0055
0075
Assignment for LTP-B: AC 230 V
AC 400 V
0008
0015 – 0030
0040/0055
0008 – 0022
0040/0055
0075/0110
UL/cUL approval
No
No
No
Type
Unit
NF LT 050 503-20
NF LT 080 503-20
NF LT 180 503-20
NF LT 300 503-00
Part number
18411088
18411096
18411118
18411126
Nominal voltage U
N
(in accord-
ance with EN 50160)
V
3 x AC 220 – 480,
48 – 62 Hz
3 x AC 220 – 500,
48 – 62 Hz
3 x AC 220 – 440, 48 – 62 Hz
Rated current I
N
A
50
80
180
300
Leakage current I
mA
< 100
< 100
< 180
< 180
Operating temperature
°C
-25 to +40
Degree of protection
IP20
IP00
Mass
kg
2.63
7.35
9.98
17.5
Assignment for LTE-B: AC
400 V
0110
–
–
–
Assignment for LTP-B: AC
230 V
AC 400 V
0075/0110
0150/0185
0220–0450
0550/0750
0150 – 0220
0300/0370
0450 – 0750
0900 – 1600
UL/cUL approval
No
No
No
No
23540052/EN – 06/2018