Fault
Possible cause
Measure
Evaluation unit display
empty.
•
Incremental encoder of adapter
is defective.
•
Measure input pulses and replace in-
cremental encoder of adapter if neces-
sary
•
Friction lining worn.
•
Inspect friction lining / cup springs and
replace if necessary
Slip torque is not
reached.
•
Friction lining worn.
•
Cup springs burned out or in-
stalled incorrectly after mainten-
ance.
•
Inspect friction lining / cup springs and
replace if necessary
9.5
Service
If you require customer service, include the following information:
•
Nameplate data (complete)
•
Nature and extent of the problem
•
Time the failure occurred and any accompanying circumstances
•
Presumed cause
•
A digital picture of the failure, if possible