Motor direction of rotation
The direction of rotation can be chosen here, which is either clockwise (CW) or
counter-clockwise (CCW). This setting is determined for each module based on
the results of the auto configuration procedure. The term “Motor direction of rota-
tion” is defined in chapter “Definition of motor direction of rotation”.
This setting is available because some applications require the motor roller to be
installed in such a way that the motor roller cable is on the opposite side of the
conveyor belt, i.e., opposite the module.
Note that there is no “Set All” button for the motor direction of rotation, since the
motor direction of rotation is defined during the auto configuration procedure.
Acceleration/deceleration
The acceleration and deceleration for a certain motor roller can be configured.
The value of the distance traveled in revolutions is used for this. The preset ac-
celeration value is 30 mm and the preset deceleration value is 30 mm.
Acceleration values can be between 0.03 meters (30 mm) and 10 meters. The
braking values are limited to 0 to 10 meters.