Operating notes
Operating Instructions – CMP ELVCD
73
7
Operation
7.1
Operating notes
Observe the following notes during operation:
•
If to command "Save parameter" is executed with an enabled drive ("En-
abled_Stop" and "Enable_RapidStop" = TRUE) in interpolation operation, the drive
signals "Ready for operation" but without the "InGear" message.
•
During homing, the command "Save parameter" is executed as well. If "homing" is
interrupted without the message "Homing Done", the drive signals "Ready for
operation" but without the "InGear" message.
To switch back to operating state "InGear", set the enable bits "Enable_Stop" and "En-
able_RapidStop" = TRUE.
7.2
ELVCD DriveManager
The following figure provides an overview of the "ELVCD DriveManager" plug-in:
[A]
[B]
[1]
[2]
[3]
[4]
[5]
[14]
[13]
[12] [11]
[10]
[9]
[8]
[7]
[6]
9007220173594763
[A] "All ELVCD inverters" area