6
Electrical installation
Connection with plug connectors
Addendum to the Operating Instructions – AH0E and AK0J Encoders
14
6.2.4
Motor connection SJ1 (M23) for motors with AK0J encoder without/with BK.. and BZ..D
brake
The wiring diagram of the plug connector depicts the contact end of the connections.
Function
Motor connection for motors with AK0J encoder
Connection type
M23, male, external thread, TE Connectivity – Intercontec products, 923 series,
SpeedTec equipment
Connection diagram
U
+
V
W
PE
D -
PE
D +
–
Assignment without brake
Contact
Signal
Description
A
U
Motor connection phase U
B
V
Motor connection phase V
C
W
Motor connection phase W
D
PE
PE connection
E
D -
Data - (serial data transfer)
F
PE
PE connection (encoder)
G
Reserved
Do not connect
H
D +
Data + (serial data transfer)
L
Reserved
Do not connect
Assignment with BK.. and BZ..(D) brake
Contact
Signal
Description
A
U
Motor connection phase U
B
V
Motor connection phase V
C
W
Motor connection phase W
D
PE
PE connection
E
D -
Data - (serial data transfer)
F
PE
PE connection (encoder)
G
Brake +
BK.. brake + / BZ..D +
H
D +
Data + (serial data transfer)
29149851/EN – 04/2020