13
∙
For positioning, we recommend that you tilt the unit slightly
backwards. In this way, the transport rollers can be used to
move it to its intended place of installation.
∙
Before it is connected to the mains, the unit must be
thoroughly checked for transport damage, including its
power cord.
∙
Clean the unit according to the instructions given in the
De-
frosting and cleaning
section.
∙
Once the unit has been positioned, wait for about 30
minutes before it is connected to the mains.
∙
If the unit has been tilted more than 30° during transport,
allow it to stand upright for at least 4 hours before it is
connected to the mains.
∙
When the unit is
fi
rst switched on, a slight smell may be
noticed. However, this will disappear once the cooling
process has begun.
Installation
∙
The appliance should be set up in a well-ventilated, dry
room.
∙
It should be operated in conditions where the relative
humidity is no more than 70 %.
∙
The product data sheet at the end of this manual contains
details of the ambient temperature range suitable for this
appliance.
∙
Do not use the appliance outdoors.
∙
Ensure that the plug is accessible and can be removed from
the wall socket at any time.
∙
Do not expose the appliance to direct sunlight, and do not
position it next to any heat sources (radiators, cookers etc).
If this cannot be avoided, however, suitable insulation must be
installed between the heat source and the unit.
∙
The unit must not be installed inside a cabinet, nor directly
below a hanging cupboard, shelf or similar object.
∙
In the case of uneven
fl
oors, the adjustable feet on the unit
can be used to compensate and ensure optimum stability.
Ventilation
Ensure that there is enough space around the unit so that the
air circulation round and behind it is not obstructed. (Rear and
sides 5 cm, top 10 cm.)
Reversible door
If required, the door may be reversed, i.e. from right-hinged
(default installation) to left-hinged.
Warning:
Always disconnect the unit from the mains before
any maintenance or repair work is carried out.
Before reversing the door, place the unit on its side, ensuring
that it rests on a soft, smooth, non-damaging surface.
1. Remove the screw covers.
2. Take out the screws and lift off the top cover.
Summary of Contents for KS 9809
Page 83: ...83 R600a GR...
Page 84: ...84 C5 H10 R600a 8 2 1 2 3 4 5 6 7...
Page 85: ...85 1 2 2 1 1 30 30 4 70 5 cm 10 cm...
Page 86: ...86 1 2 3 4 5 3 6 B A 7...
Page 87: ...87 8 9 180 10 11 Normal 3 5...
Page 88: ...88 24 2 5 12 5 3 5...
Page 89: ...89 24 0 30 30 30 4...
Page 90: ...90 KS KS 9809 A kWh 217 160 15 24 12 N ST C 16 38 C 43 dB a x x mm 1440 x 551 x 554 45 5...
Page 91: ...91 R600a RU...
Page 92: ...92 C5 H10 R600a 8 2 1...
Page 93: ...93 2 3 4 5 6 7 1 2 2 1 1 30 30 4 70 5 10...
Page 94: ...94 1 2 3 4 5 3 6 B A 7...
Page 95: ...95 8 9 180 10 11 Normal 3 5...
Page 96: ...96 24 2 5 12 5 3 5...
Page 97: ...97 24 0 30 30...