Seura S1 32

6

Display Requirements

Operation and Storage Requirements

The ambient temperature for operating the device is between 41 to 122 degrees Fahrenheit. Do not install the device in the proximity of heat sources, 
such as heating pipes, heaters, furnaces or other devices that radiate heat. Mount the device in such a way that it is protected against moisture. 
Trouble free operation is ensured up to 75% air humidity. To prevent fire or electric shock, never allow liquids to enter the unit. The product must be 
stored in dry and well-ventilated rooms, without extreme temperature fluctuations. Heat sources and aggressive active substances may not be stored 

in the proximity of the device. The required storage temperature is 32° F - 140° F at an air humidity of 5 - 85% RH non-condensing. The device must be 

stored in the complete packaging, as delivered.

Installation Environment

Avoid direct light or sun exposure, direct proximity to heat sources, outdoor installation. The product is specifically designed for indoor use only. There 
is the danger of fire and of electric shock and damage to the device if it is operated outdoors. Do not place any heat sources such as radiators and 
heat registers, etc. near the monitor. To reduce eye strain, avoid installing the Séura Mirror Display against a bright background such as a window. 
Position the monitor at the height of your eye level. Position the monitor directly in front of you at a comfortable viewing distance. 

Installation

Have this product installed by qualified personnel only. Use the mounting systems which are specified or recommended by Séura. Install the product 

in a way that it is fixed properly and take care that children are not exposed to danger. Please take extra care during installation, avoid impacts. Before 
cabling your monitor, check that the power is off. To avoid any possibility of electric shock, always connect your equipment to properly grounded 

outlets. Use of power cords or adapters other than those provided may cause fire or malfunction. Place this product as close to the power socket as 
possible. Leave enough space to insert and remove the power plug on demand. Even if you switch off the product with your remote control, power is 

not cut off unless the power cord is unplugged.

The device may only be operated with the provided power adapter. The rated voltage is indicated on the product label. The device is factory-set to 

the optimal operating voltage (see Technical Specification). Use only power cords and plugs that are suitable for your local electrical outlets. Install 
the power cords in such a way that it does not obstruct anyone. Ensure furthermore that the cable is not clamped and that it cannot be pulled out 

accidentally from the power adapter. Do not install the power cords in the proximity of heating elements and never place heavy items on the cable or 
power adapter. Do not modify or arbitrarily repair the power cords.

CAUTION

Do not use any power cords or adapters other than those provided with this product! Use of power cords or adapters other than those provided 

with this product may cause fire, electric shock or malfunction. If several kinds of power cords are provided with this product, use the one that fits 
your power socket. Do not let the adapter hang down while using. Do not cover or wrap the adapter. Leave space around the adapter to prevent 
overheating. The individual components can be destroyed, if the polarity is reversed or an incorrect connection is used. A goodwill replacement is not 
possible in such cases, since each device is submitted to meticulous quality inspections prior to shipping. The connecting plugs must be attached in 
such a way that the connector is held firmly. Have trained technical personnel install the electrical facilities necessary for mounting. The power adapter 
must be installed in ventilated areas due to heat emission. Connect the power cord to a grounded outlet. Never cut or damage the power cord.

Please disconnect the device from the power adapter in the following cases:

1. The device is out of use for a lengthy period.

2. The device malfunctions or displays other unusual features, necessitating maintenance work.

3. During a thunderstorm.

Please plan the positioning of the power adapter and the source cables before proceeding with the structural measures and positioning of the Séura 

Mirror Display. Observe the protection zones when placing the power adapter! For in-wall applications please bear in mind that the power adapter has 

to be placed beyond the inset due to heat emission. Optional 25’ or 50’ adapter extension cables may be purchased from Séura.

NOTE

The power adapter should be adequately secured to prevent it from becoming unstable and/or falling. Make sure the power source circuits are properly 

grounded. Use the supplied power cord in order to connect it to the power source. If your installation requires a different power cord, be sure to use an 

officially approved power cord displaying the mark of the safety agency that defines the regulations for power cords in your country. Please consider 
that the AC outlet for the power adapter is placed within reach of the Séura Mirror Display and should be easily accessible in case it needs to be 
powered off.

Install the unit in a dry environment where the operating ambient temperature will not exceed 40°C / 104°F. Also, don’t position the power adapter on 
top of the Séura monitor system in order to prevent thermal overload. Ensure that your installation complies with your national and local safety rules. 

Any servicing, adjustment, maintenance or repair must be performed only by service-trained personnel.

Ensure the power adapter is installed in an accessible location, to access it easily in case of a defect. If you choose to place the power adapter in a 

separate space, take care that ventilation is present, because the power adapters need convection cooling for stable working conditions.

When placing the power adapter in a fully enclosed space, make sure the air flow around the sides and top of the power adapter is not restricted. 
According to a common rule of thumb please calculate the length of the power adapter plus an additional gap of at least 100mm all around for DC 12V 
power adapters and 200mm for DC 24V power adapters.

Summary of Contents for S1 32 " -65 "

Page 1: ...S1 3 2 6 5 U S E R M A N U A L Premier Series VA N I S H I N G M I R R O R D I S P L AY www seura com ...

Page 2: ...t and be easily accessible The TV should be connected to a grounded GFCI protected main socket outlet WARNING If you manipulate against the recommended usage serious injury or death to user may result To protect against electric shock do not immerse the power cord power plug or product in water or other liquid Do not overload AC outlets or extension cords Overloading can cause fire or electric sho...

Page 3: ...other liquid Do not overload AC outlets or extension cords Overloading can cause fire or electric shock Close adult supervision is necessary when any product is used by or near children Do not operate any product with a damaged cord or plug or operate it after the appliance malfunctions or has been damaged in any manner Do not let the power cord come in contact with hot surfaces To electrically di...

Page 4: ... Menu OSD 11 Input Source Selection 11 On Screen Display Menu 11 Image Settings 11 Display Settings 12 Audio Settings 12 OSD Settings 13 Setup Settings 13 Service Settings 14 15 USB Media Player 15 I N T E G R A T I O N A N D C O N T R O L RS 232 16 RS 232 Command Table 18 Discrete IR Codes 19 T R O U B L E S H O O T I N G A N D T E C H N I C A L D E T A I L S Troubleshooting 20 Technical Features...

Page 5: ...at illuminates the room not the Mirror Display DO NOT position lighting directly on the Mirror Display This will wash out the picture and hinder the product s performance DO DO DO NOT DO NOT Lighting and Performance Care and Maintenance Our patented mirror technology has been developed to completely protect the mirror surface and allow easy maintenance Please follow the guidelines listed for prope...

Page 6: ...pters other than those provided with this product may cause fire electric shock or malfunction If several kinds of power cords are provided with this product use the one that fits your power socket Do not let the adapter hang down while using Do not cover or wrap the adapter Leave space around the adapter to prevent overheating The individual components can be destroyed if the polarity is reversed...

Page 7: ... TOLERANCES FRACTIONAL 1 8 3mm ANGULAR MACH 1 0 ANGULAR BEND 1 0 TWO PLACE DECIMAL 03 8mm THREE PLACE DECIMAL 015 4mm N A Date Created so46S1S Sales Order Inv Number S S 4932 46 S1 PR NI Item Revised Date Revised Date www seura com 1 800 95 SEURA PH 920 857 9069 FAX 920 857 9490 49 32 412 40 412 434 434 2212 A 46 Monitor Viewable Screen 1 Lift Off Clearance Required 2716 278 1 1 16 3 16 DETAIL A S...

Page 8: ... Guide CC and Last buttons have no function on Séura S1 Premier Series Displays Mute turns on or off all audio output Sleep designates power off after a specified time Zoom configures ratio and appearance of picture Input designates displaying content source Display displays input and resolution information Use Volume arrows to increase or decrease volume level Speaker Output IR Input Receiver IR ...

Page 9: ...nting Clip SIDE VIEW DETAIL SCALE 1 3 Removable Side Panel Mirror Face Interface Plate Interlocking Brackets 46 S1 HIGH DEFINITION MONITOR SPECIFICATIONS Display Type TFT Thin Film Transistor Backlight LED Active Screen Area WxH 40 08 W x 22 56 H Picture Format 16 9 Physical Resolution 1920 x 1080 Horizontal Viewing Angle Typical Total 176 Left 88 Right 88 Vertical Viewing Angle Typical Total 176 ...

Page 10: ...inputs Connecting a Home Automation System With the RS 232 interface 9 pin d subminiature connector male you can connect a cross linked serial cable for communication with a home automation system PC etc The baud rate is adjustable from 9600 up to 38400 the default value is 38400 RS 232 access see section Service Settings Connecting an external IR transmitter and Receiver With the IR input interfa...

Page 11: ...ay Menu OSD w a t e r p r o o f last ok enter channel volume cc guide mute sleep zoom input display menu exit 2010 Remote Redesign Final w a t e r p r o o f last ok enter channel volume cc guide mute sleep zoom input display menu exit 2010 Remote Redesign Final w a t e r p r o o f last ok enter channel volume cc guide mute sleep zoom input display menu exit 2010 Remote Redesign Final w a t e r p r...

Page 12: ...u can define the volume at startup Your options Last User If you choose Last the volume at power on is the same as at power off before the Séura Mirror Display went into standby default setting If you choose User you can define the volume level the Séura Mirror Display will set after standby SPEAKER PROTECTION The Speaker Protection feature prevents a quick increase in volume to be passed on to th...

Page 13: ...ENCY Within the OSD Transparency menu you can adjust the Transparency of the OSD menu Your options 0 25 50 75 SÉURA MIRROR DISPLAY MODEL FIRMWARE VERSION INFO The Séura Mirror Display Model and Firmware Version Info indicate the name of the device and the version of the installed Firmware SAVE CURRENT SETTINGS Within the Save Current Settings menu you can save your current device settings LOAD SET...

Page 14: ...n the following order HDMI 1 2 3 Component If a signal is found then the Mirror Display will select this port See also Signal Loss Timer below SIGNAL LOSS TIMER With the Signal Loss Timer setting you can set the time the Input Scan will be performed If Signal Loss Timer is set off the search will continue indefinitely or until a signal is found If Signal Loss Timer is set to 5 10 30 60 120 seconds...

Page 15: ...8k bit rate 32k 320k AAC M4A AAC sample rate 16k 48k bit rate 32k 192k Text TXT OSD cont USB Media Player HDMI CEC With the HDMI CEC Consumer Electronics Control setting you can enable or disable the Mirror Display to be controlled with the remote control of a CEC compatible connected external media source RS 232 ACCESS With the RS 232 Access setting you can de activate the RS 232 functionality Wi...

Page 16: ...ng next command Minimum 2 seconds delay before resending a command if no response received Minimum 500ms delay between commands Minimum 5 seconds delay after sending 20 commands RS 232 Communication Parameters Command Structure Baud rate is configurable from the OSD Service Menu Default baud rate is 38400 Default access password for Service Menu is 1 2 3 4 Examples for identifiers PWR BAS SRC Sepa...

Page 17: ... 1 byte Required Identifier Key identifier case sensitive 3 bytes Required Separator Character symbol colon 1 byte Optional Value Value 3 bytes Optional Terminator CR carriage return 0x0D 1 byte Required Code Error Message Description ERR 001 Access denied Command disabled by unit settings Example Trying to switch to USB input while this input is dis abled in Service Settings ERR 002 Not available...

Page 18: ...OSA ON OSA OFF OSA ON OSA OFF Get OSD Access Status Access ON Access OFF OSA OSA ON OSA OFF Function Command Tx ACK Rx OSD Toggle OSD TOG OSD TOG OSD ON open OSD OFF close OSD ON OSD OFF OSD ON OSD OFF Get OSD Status ON OFF OSD OSD ON OSD OFF Input HDMI 1 Input HDMI 2 Input HDMI 3 Input Component Input USB DMP SRC HD1 SRC HD2 SRC HD3 SRC RGB SRC USB SRC HD1 SRC HD2 SRC HD3 SRC RGB SRC USB Get Inpu...

Page 19: ...0A 001F 000A 001F 000A 001F 000A 001F 000A 001F 000A 0047 000A 001F 000A 074A 000A 0047 000A 001F 000A 001F 000A 001F 000A 001F 000A 001F 000A 0047 000A 0047 000A 0047 000A 0047 000A 0047 000A 0047 000A 0047 000A 001F 000A 0047 000A 0652 2 0000 006B 0000 0020 000A 0047 000A 001F 000A 001F 000A 001F 000A 001F 000A 001F 000A 0047 000A 001F 000A 001F 000A 001F 000A 001F 000A 001F 000A 001F 000A 0047 ...

Page 20: ... remote control and check the audio connection cable s Make sure that the Volume Limit setting in the Service Settings menu has been set to an audible value Remote control doesn t work Press a button on the remote control and check that the status LED of the Mirror Display flashes briefly If it doesn t replace the batteries of the remote control with new ones NOTE If the above troubleshooting hint...

Page 21: ...cable 1 x mini jack 3 5mm IR Output LED 1 x mini jack 2 5mm Video HDMI 480i 480p 576i 576p 720p 1080i 1080p Component YPbPr YCbCr 480i 480p 576i 576p 720p 1080i 1080p Audio Output Speaker Output 2 x 8W RMS 8Ω per channel Multimedia Player USB Software Update USB Autostart Yes Signal Scan Yes Hotel Mode Yes RS 232 Yes Noise Reduction 3D USB Media Support File Extension Video Audio Movie avi DivX Xv...

Page 22: ...F 20 90 1 8 lbs 42 200W 8 3A 100 240V AC 24V DC 32 104 F 20 90 1 8 lbs 46 200W 8 3A 100 240V AC 24V DC 32 104 F 20 90 1 8 lbs 55 600W 25 0A 100 240V AC 24V DC 32 104 F 20 90 7 8 lbs 65 600W 25 0A 100 240V AC 24V DC 32 104 F 20 90 7 8 lbs Power Adapters Power Supply for 32 46 Mirror Displays Power Supply for 55 65 Mirror Displays ...

Page 23: ...tructions J The effects of fire flood lightning electrical surges water and other liquid infiltration smoke and other substances not intended to come into contact with a Product including any such substances contact with a Product as the result of acts of God K The improper or faulty installation setup or adjustment of a Product L A Product s repair attempted repair or total or partial disassembly...

Page 24: ... Séura 2013 All Rights Reserved 4 10 13 Séura Inc 1230 Ontario Road Green Bay WI 54311 800 95 SEURA t 920 857 9069 f 920 857 9490 8 0 0 9 57 3 872 www seura com ...

Reviews: