23
■
1, 2, 3, 4, 6, 8,12 y 24 h.
○
Repeat missing targets:
If a prism could not be measured, at the end of the round it will try
the measurement again.
○
Days to measure
: Activate/deactivate the days of the week that measurement is required.
Days start at 0:00 UTC
Laser
This option switch on or switch off the laser
Mode
It is the option to select the measurement mode. We can choose between:
○
Manual (M)
○
Autolock (A)
○
FineLock (FL)
○
FineLock Long Range (LR)
○
Direct Reflex (DR)
The preselected mode will prevail when measuring the point.
Chg Face
The Total Station change between Face1 and Face2
Turn To
By pressing this button, You can select an existing point from the list and turn to it. Also, You can type or
enter the horizontal and vertical angle (gon) at which you want to rotate the total station.
SETTOPSURVEY, S.L. Bofarull 14, 08027 Barcelona (Spain) Phone: (+34) 93 340 05 73 Fax: (+34) 93 351 95 18