Setra Systems Multi-Sense 231 Manual Download Page 2

Phone: 800-257-3872  •  Fax:  978-264-0292  •  setra.com    © Setra Systems, Inc.  All rights reserved.  The Setra Systems name and logo are registered trademarks of Setra Systems, Inc.

Multi-Sense

®

   

Model 231

Multi-Configurable, Wet-to-Wet Differential Pressure Transducer

GENERAL SPECIFICATIONS

Electrical Data (Voltage)

Performance Data

Circuit

3-Wire

Accuracy RSS

(at constant temp.)                            

Excitation

15 to 30 VDC/18 to 30 VAC (Reverse Excitation 
Protected)

Pressure Ranges A, B, C

±1.0% FS

Output

1

0 to 5 VDC, 0 to 10 VDC, 1 to 5 VDC

Pressure Ranges D

±2.0% FS

Output Impedance

30 Ohms

Pressure Ranges

Circuit Consumption

8 mA (typ.) at 5 VDC, 8 mA (typ) at 10 VDC, 40 
mA (typ.) at 18-30 VAC

Range Code

A

B

C

D

Max. Line Pressure

MS1

50

25

10

5

50

Electrical Data (Current)

MS2

100

50

20

10

100

Circuit

2-wire (Reverse Excitation Protected)

MS3

250

125

50

25

250

Output

2

4 to 20 mA

Pressure Media

External Load

0 to 250 Ohms

Liquids or Gases Compatible with 17-4 PH Stainless Steel

Note: Hydrogen not recommended for use with 17-4 PH stainless steel

Min. Supply Voltage

15 VDC + 0.02 x (Resistance of receiver plus 
line)

Thermal Effects

5

Max. Supply Voltage

30 VDC + 0.004 x (Resistance of receiver 
plus line)

Compensated Range 

°F (°C)

+32 to +130 (0 to +54)

Physical Description

Zero/Span Shift %FS/100

°F (50°C)

2.0 (1.8)

Case

Die Cast Aluminum, Powder Coated

Warm-up Shift

<0.12% FS

Pressure Fittings

1/8-18 NPT Internal

Response Time

1 to 5 sec. (selectable)

Electrical Connection

1/2 in. Conduit

Proof Pressure

2 x Full Scale

Size

4.0 x 6 x 2 in. (102 x 152 x 51 mm)

Burst Pressure

15 x Full Scale (50 PSI), 10 x Full Scale (75 x 
150 PSI), 8 x Full Scale (250 PSI)

Weight

1.5 lb

1

 Calibrated into a 50K ohm load, operable into a 5000 ohm load or greater.

2  

Calibrated at factory with a 24 VDC loop supply voltage and a 250 ohm load. 

3  

Operating temperature limits of the electronics only.  Pressure media temperatures may be 

considerably higher or lower.

4  

RSS of  Non-Linearity, Hysteresis, and Non-Repeatability. 

5  

Units calibrated at nominal 70˚F. Maximum thermal error computed from this datum. 

Specifications subject to change without notice.

Sensor Vacity Volume

0.2 cc

Environmental Data

Operating

3

 Temperature 

°F (°C)

 

-4 to +185 (-20 to -85)

Storage Temperature 

°F (°C)

 

-4 to +185 (-20 to +85)

MODEL 231 DIMENSIONS

5.6

141

6.0

152

0.3

9

R 0.1

2

1.2

31

2.0

51

1.7

42

1.0

24

1.6

40

1/2” Conduit 

Opening

High

Low

5.2

131

1/8” NPTF

IN

MM

4.6

117

4.8

122

4.0

102

2.0

51

Summary of Contents for Multi-Sense 231

Page 1: ...ti range functionality allows the user to hold less inventory and add additional flexibility in the field Quick Simple Installation The 231 provides the user with an optional 3 or 5 valve ma chined brass manifold which can save money on installation and maintenance The single piece construction of the brass body has no internal process connections eliminating the risk of internal leaks Robust Encl...

Page 2: ...fects5 Max SupplyVoltage 30VDC 0 004 x Resistance of receiver plus line Compensated Range F C 32 to 130 0 to 54 Physical Description Zero SpanShift FS 100 F 50 C 2 0 1 8 Case Die Cast Aluminum Powder Coated Warm up Shift 0 12 FS Pressure Fittings 1 8 18 NPT Internal ResponseTime 1 to 5 sec selectable Electrical Connection 1 2 in Conduit Proof Pressure 2 x Full Scale Size 4 0 x 6 x 2 in 102 x 152 x...

Page 3: ...nection 1 4 NPT V3 SHUT OFF VALVES SHUNT VALVE Manifold Block Brass Valves 5 V1 for connection to port V2 for connection to port V3 for equalizing pressure V4 for connection to external gauge or alternate plumbing configuration V5 for connection to external gauge or alternate plumbing configuration Valve Type 90 Degree On Off Process Connection 1 4 18 NPT Internal Thread 4 00 102 38 10 31 8 7 21 1...

Page 4: ...S13VN Model 231 0 to 5 PSID up to 50 PSI 3 Valve Manifold and No LCD Display Valve A1 High Low Pressure Remote Sensor High Pressure Remote Sensor Valve B1 Low Valve A High Side Valve Valve B Low Side Valve 1 Valves not included Examine the pressure application and determine what is the Highest System Line Pressure Determine what is the Differential Pressure being measured Find the MAX Line Pressur...