background image

TABLE 1

CONNECTIONS 522 / 526 SERIES

TYPE

NUMBER

CE

CONNECTOR

mV

4-20mA

VOLTAGE

IN+

OUT+

OUT-

IN-

EARTH

IN+

IN-

EARTH

IN+

COM

OUT+

EARTH

522BP-E1

YES

MINI DIN STYLE

1

2

3

E

522BP-NA

YES

CABLE WEATHER PROOF

R

Y

BL

G

S22BP-N1

YES

CABLE USA

R

W

G

BK

522BP-E1

YES

MINI DIN STYLE

1

2

E

1

2

3

E

522XX-NA

YES

CABLE WEATHER PROOF

R

BK

DRAIN

R

BK

W

DRAIN

522XX-N1

YES

CABLE USA

R

BK

DRAIN

R

BK

W

DRAIN

526BP-B1

YES

8-4P

A

B

C

D

526BP-C2

YES

10-6P

A

B

C

D

526BP-E2

YES

LARGE DIN

1

2

3

E

526BP-UA

YES

MOLDED IMMERSIBLE

R

Y

B

W

DRAIN

526BP-UA

YES

MOLDED IMMERSIBLE

R

Y

B

W

DRAIN

526BP-A2

YES

CONDUIT LEADS

R

W

G

BK

526XX-B1

YES

8-4P

A

B

D

A

C

B

D

526XX-B3

YES

10-6P

A

B

E

A

C

B

E

526XX-C2

YES

LARGE DIN

1

2

E

1

2

3

E

526XX-UA

YES

MOLDED IMMERSIBLE

R

BL

DRAIN

R

W

Y

DRAIN

526XX-UA

YES

MOLDED IMMERSIBLE

R

BL

DRAIN

R

W

Y

DRAIN

526XX-A1

YES

CONDUIT LEADS

R

BK

G

R

BK

W

G

OUTPUT

SUPPLY VOLTAGE

OUTPUT

SUPPLY VOLTAGE

BP

      0 to 100mV

10V d.c.

27

    1 to 5V

6.5 to 35V d.c.

11

       4 to 20mA

7 to 35V d.c

24

    0.5 to 5.5V

7 to 35V d.c.

28

       1 to 6V

7.5 to 35V d.c

2B

   0 to 5V

6.5 to 35V d.c.

2R  

     1 to 11V

12.5 to 35V d.c

2C  

 0 to 10V

11.5 to 35V d.c.

159 Swanson Road,  Boxborough,  MA 01719-1304
                           Tel: 800-257-3872 / 978-263-1400

OP522/526  Rev A  11/03

Summary of Contents for 526

Page 1: ...Installation Guide MODELS 522 526 Pressure Transducers 560550 0087 Rev A 1 800 257 3872 TOLL FREE 1 978 264 0292 FAX www Setra com Web Site ...

Page 2: ...Setra offers a complete line of products for these industries Industrial HVAC Test Measurement Barometric Ultra High Purity Sanitary ...

Page 3: ...y potential hazards associated with their storage handling or use The products which our Company supplies may be classified as Electrical Electro Mechanical and Electronic equipment These products are tested and supplied in accordance with our published specifications or individual special requirements that are agreed in writing at time of order They are constructed so as not to affect adversely t...

Page 4: ...CE mark only applies when connection is made with Setra Systems approved cable see APPROVED CABLE section and is connected as shown below Millivolt Output Transducers Four wire shielded cable should be used with the cable shield connected to the instrumentation ground The cable shield should not be connected to the transducer body High Output Transducers The shield of the cable must be grounded at...

Page 5: ...mpany carefully packed and accompanied by a detailed failure report See RETURN TO FACTORY WETTED PARTS 316 and 17 4 PH stainless steel plus Nickel Braze to BS1845 NK3 HTN2 SERVICING The transducer cannot be repaired locally and if damaged should be returned to Setra Systems with the following 1 Name and phone number of person to contact 2 Shipping and billing information 3 Full description of malf...

Page 6: ... will occur until cleared It may ultimately be returned to you and subject to a transportation charge MAINTENANCE Routine Inspection Not required except for periodic inspection of the cable and connector to ensure that these are neither damaged nor softened by incompatible liquid ...

Page 7: ...E R Y B W DRAIN 526BP UA YES MOLDED IMMERSIBLE R Y B W DRAIN 526BP A2 YES CONDUIT LEADS R W G BK 526XX B1 YES 8 4P A B D A C B D 526XX B3 YES 10 6P A B E A C B E 526XX C2 YES LARGE DIN 1 2 E 1 2 3 E 526XX UA YES MOLDED IMMERSIBLE R BL DRAIN R W Y DRAIN 526XX UA YES MOLDED IMMERSIBLE R BL DRAIN R W Y DRAIN 526XX A1 YES CONDUIT LEADS R BK G R BK W G OUTPUT SUPPLY VOLTAGE OUTPUT SUPPLY VOLTAGE BP 0 t...

Reviews: