background image

Description

ADMIRAL Compact is a ready to install WC pan with an inte-
grated pump / macerator. The unit is for domestic use only.

Installed and used correctly, ADMIRAL Compact will give
consistent and reliable service.

Operation

ADMIRAL Compact is operated by an electronic programm.
It has 2 functions:
· It will macerate the WC waste and pump it away to the drain:
a push of the button will set in motion the 25 second cycle to
the above.
· It will pump away the waste water from a washbasin. In this
case, the motor will activate automatically when the water
enters. 

Applications

The unit is for domestic use. Applications are discharge of a
WC and a washbasin. All other application and commercial
use are to proscribe.

Technical data

Max. vertical pumping

3m

Max. horizontal pumping

30m

Evacuation diameter

32mm

Normal power rating

800W

Medium water temperature

35°C

Electric class

I

Noise level

61dBA

Net weight

26 Kg

Installation

a) Attaching the toilet to the floor (fig. 7a)
Find a suitable location, place the unit on the floor without attaching it. Mark the per-
imeter of the bowl on the floor and mark where the bracket screws will be, (rear screw
holes). Remove the bowl. Measure 15mm inwards from the line and mount the L-
brackets on the floor. 
Note: To reduce noise level when the toilet ist installed on a hard floor, you may want
to insert an insulating material between the floor and the bowl. 

b) Connection of the discharge (fig.  7b)
· Push the plastic insert and rubber flap (H) down into the rubber discharge pipe until
it is flush with the lip.
· Point the non-return valve flap so that it opens in the direction of flow of the dis-
charge. Now place the discharge elbow over the flap assembly.
· Secure the base of the elbow (I) to the discharge pipe and non-return valve flap
assembly with the jubilee clip (C) provided.
Attention: Ensure that you do not twist the discharge pipework inside the unit.
Attention: The horizontal portion of the discharge pipe should be installed in a gra-
vity flow (at least 1%). Avoid any low parts in the discharge pipe.
Attention: Protect pipes against freezing with appropriate insulation. If the toilet is
installed in an unheated location during freezing periods protect it as follows:
- shut off the water supply
- activate one cycle without water
- pour antifreez in the bowl (2 liters)
-flush the toilet
Attention: Any bends in the discharge pipe run should be smooth radius bends. If
using plastic pipe, two 45 degree offsets can be used to form a smooth bend. 
Note: We would recommend that a drain-off point is installed to allow the discharge
pipework to be drained down before any service work.

c) Connection of a washbasin (fig. 7c)
If you want to connect a washbasin to your ADMIRAL Compact unit, please refer on
fig. 1 to 3

d) Connection to the water supply (Abb. 7d)
Connect the water supply hose to a shut off valve.  
Attention: For a correct rising, the water pressure should be at least 1.7 bar.
Note: In an area where the water is not pure, we advise you to add a filter between
the shut off valve and the toilet to prevent clogging of the solenoid valve. 

e) Connection to the electrical supply
Electrical installations should be build by specialists. The electrical installation should
be installed after finishing the installation of your macerator unit.
The electrical installation must be in accordance with the current electrical code. The
product should be connected at all the times to the electrical supply. 

GB

SETMA (Deutschland) GmbH

Siemensstrasse 3

D-85716 Unterschleissheim

Tel. +49 (0)89 / 317 13 19

Fax +49 (0)89 /317 57 66

List of accessories included (fig. 4)

Dimensions (fig. 5)

Performance curve (fig. 6)

Summary of Contents for Admiral Compact

Page 1: ...Com p Com pact act Montage und Betriebsanleitung Installation and operating instructions SETMA Deutschland GmbH Siemensstrasse 3 D 85716 Unterschleissheim Tel 49 0 89 317 13 19 Fax 49 0 89 317 57 66...

Page 2: ...17 57 66 D 7d 7a 7b Hauteur m Vertical Height m F rderh he m Altezza m Opvoercapaciteit m Altura m Loftehojde m Lyfth jd m D bit l min Flowrate l min F rderstrom l min Portata l min Afvoercapacitaet l...

Page 3: ...e C befestigen 32er Rohr mit Schelle D befestigen Achtung bei der Abgangsleitung handelt es sich um eine Druckleitung Verwenden Sie bitte ausschlie lich zugelassenes Rohrmaterial kein HT Rohr verwende...

Page 4: ...Monate eine Entkalkung durchzuf hren Auf keinen Fall S ure oder Chlorbleiche verwenden Tipps f r ein langes Leben Regelm iges Reinigen nur normales Toilettenpapier benutzen Feuchttoilettenpapiere lass...

Page 5: ...se befindliches Restwasser entleeren Innenf rderstutzen Teil 57 und 58 reinigen Deckeldichtung einfetten Deckel aufsetzen und festschrauben Ger t zusammenbauen Garantiebestimmungen Der Hersteller biet...

Page 6: ...e elbow I to the discharge pipe and non return valve flap assembly with the jubilee clip C provided Attention Ensure that you do not twist the discharge pipework inside the unit Attention The horizont...

Page 7: ...the water in your area We advise you to do it at least once a year Do not put acids caustic sodas or solvents down ADMIRAL Compact For a long life of your unit Regular cleaning Please use only normal...

Page 8: ...or case Remove the clear hose from the pneumatic push button 11 Remove the water supply hose 6 Unscrew the gear clamp 20 between the elbow and the case of the motor Remove the motor from the bottom of...