16 of 38
cRIO LVDT 9312 Module
Technical Description
Issue
05
24/05/2022
3.4.1.6
A
DDING
LVDT9312
M
ODULES
T
O
T
HE
P
ROJECT
V
IA
T
HE
D
ISCOVERY
-F
UNCTION
(
NOT RECOMMENDED
)
The LabVIEW function “Discover C
-
Series Modules” automatically detects and integrates cRIO modules which are
plugged into an R-Series Expansion Chassis or a cRIO-Chassis.
This initiates LabVIEW to check the chassis for cRIO modules.
When the search procedure is complete, LabVIEW adds an module item for each detected module and a virtual
folder including the module IOs.
Automatik Detektion, with wrong name for Module
It is important that the I/O names of the Module match the names expected by the driver. Normally the correct
I/O name are created by LabVIEW within the discovery function. However on some LabVIEW versions the I/O
Names are different. In this case you need
to change the names of the I/O’s to the names used in the example
project, or copy the I/Os and module from the example project and delete the automatically created ones.